TABLE III. Group A inspection for device types 04 and 10 - Continued. 11
Subgroup |
Symbol |
MIL- STD- 883 method |
Case X |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
13 |
14 |
15 |
16 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
25 |
26 |
28 |
29 |
32 |
Algorithm |
Measured terminal |
Test limits |
Unit |
|
Case J |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
Min |
Max |
||||||
Test no. |
A7 |
A6 |
A5 |
A4 |
A3 |
A2 |
A1 |
A0 |
DQ0 |
DQ1 |
DQ2 |
VSS |
DQ3 |
DQ4 |
DQ5 |
DQ6 |
DQ7 |
CE |
A10 |
OE |
WE |
A9 |
A8 |
VCC |
||||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C. |
|||||||||||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C. |
|||||||||||||||||||||||||||||||
4 TC=+25°C |
CIN COUT |
3012 |
65 66 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
GND " |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
Input Output |
10 12 |
pF pF |
|||
7 TC=+25°C |
I1O VDR |
Function tests |
67 68 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
" " |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
71 81 |
4.5 V 2.0 V |
Pattern 5 Pattern 4 |
||||
8 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC = +125°C and -55°C. |
|||||||||||||||||||||||||||||||
9 TC=+25°C |
Func- tional tests |
69 70 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
GND " |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
91 91 |
4.5 V 5.5 V |
Patterns 1,3,5 Patterns 1,3,5 |
DQ DQ |
||||
tELQV tELQV tAVQV tAVQV |
71 72 73 74 |
" " " " |
4.5 V 5.5 V 4.5 V 5.5 V |
Pattern 3 Pattern 3 Pattern 3 Pattern 3 |
DQ DQ DQ DQ |
90 " " " |
ns " " " |
|||||||||||||||||||||||||
10 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = +125°C. |
|||||||||||||||||||||||||||||||
11 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = -55°C. |
See footnotes at end of device type 04.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business