TABLE III. Group A inspection for device types 03 and 09. 11
Subgroup |
Symbol |
MIL- STD- 883 method |
cases R,Y |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
Algorithm |
Measured terminal |
Test limits |
Unit |
|
Test no. |
A0 |
A1 |
A2 |
A3 |
A4 |
A5 |
A6 |
DQ |
WE |
vSS |
cE |
DIN |
A7 |
A8 |
A9 |
A10 |
A11 |
A12 |
A13 |
vcc |
Min |
Max |
||||||
1 Tc=+25°c |
Icc1 Icc2 Icc3 Icc4 |
3005 |
1 2 3 4 |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
31 " " " |
21 GND " " |
GND " " " |
0.8 v 5.2 v 2.2 v 1.7 v |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
21 GND " " |
5.5 v " " 2.0 v |
1 MHz |
vcc " " " |
50 100 5 50 |
mA µA mA µA |
|
IIL |
3009 |
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 |
GND vcc " " " " " " " " " " " " " " " |
vcc GND vcc " " " " " " " " " " " " " " |
vcc vcc GND vcc " " " " " " " " " " " " " |
vcc " " GND vcc " " " " " " " " " " " " |
vcc " " " GND vcc " " " " " " " " " " " |
vcc " " " " GND vcc " " " " " " " " " " |
vcc " " " " " GND vcc " " " " " " " " " |
vcc " " " " " " GND vcc " " " " " " " " |
" " " " " " " " " " " " " " " " " |
vcc " " " " " " " GND vcc " " " " " " " |
vcc " " " " " " " " GND vcc " " " " " " |
vcc " " " " " " " " " GND vcc " " " " " |
vcc " " " " " " " " " " GND vcc " " " " |
vcc " " " " " " " " " " " GND vcc " " " |
vcc " " " " " " " " " " " " GND vcc " " |
vcc " " " " " " " " " " " " " GND vcc vcc |
vcc " " " " " " " " " " " " " " GND vcc |
vcc " " " " " " " " " " " " " " " GND |
5.5 v " " " " " " " " " " " " " " " " |
A0 A1 A2 A3 A4 A5 A6 WE cE DIN A7 A8 A9 A10 A11 A12 A13 |
-1 " " " " " " " " " " " " " " " " |
1 " " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " " |
|||
IIH |
3010 |
22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 |
" GND " " " " " " " " " " " " " " " |
GND vcc GND " " " " " " " " " " " " " " |
GND GND vcc GND " " " " " " " " " " " " " |
GND " " vcc GND " " " " " " " " " " " " |
GND " " " vcc GND " " " " " " " " " " " |
GND " " " " vcc GND " " " " " " " " " " |
GND " " " " " vcc GND " " " " " " " " " |
GND " " " " " " vcc GND " " " " " " " " |
" " " " " " " " " " " " " " " " " |
GND " " " " " " " vcc GND " " " " " " " |
GND " " " " " " " " vcc GND " " " " " " |
GND " " " " " " " " " vcc GND " " " " " |
GND " " " " " " " " " " vcc GND " " " " |
GND " " " " " " " " " " " vcc GND " " " |
GND " " " " " " " " " " " " vcc GND " " |
GND " " " " " " " " " " " " " vcc GND GND |
GND " " " " " " " " " " " " " " vcc GND |
" " " " " " " " " " " " " " " " vcc |
" " " " " " " " " " " " " " " " " |
A0 A1 A2 A3 A4 A5 A6 WE cE DIN A7 A8 A9 A10 A11 A12 A13 |
" " " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " " |
|||
IOLZ |
3020 |
39 |
GND |
" |
2.2 v |
" |
DQ |
" |
" |
" |
||||||||||||||||||
IOHZ |
3021 |
40 |
vcc |
" |
2.2 v |
" |
DQ |
" |
" |
" |
||||||||||||||||||
vOL |
3007 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
" |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
4.5 v |
DQ |
0.4 |
v |
|||
vOH |
3006 |
42 |
51 |
51 |
51 |
51 |
51 |
51 |
51 |
51 |
51 |
" |
51 |
51 |
51 |
51 |
51 |
51 |
51 |
51 |
51 |
4.5 v |
DQ |
2.4 |
v |
|||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except Tc = +125°c. |
|||||||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except Tc = -55°c. |
See footnotes at end of device type 03.