MIL-M-38510/291B
2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersede applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Qualification. Microcircuits furnished under this specification shall be products that are manufactured by a manufacturer authorized by the qualifying activity for listing on the applicable qualified manufacturers list before contract award (see 4.2 and 6.3).
3.2 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535 and as specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein.
3.3 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535 and herein. Die bonding may be performed using conductive silver paste or other epoxy. All epoxies must be qualified to test method 5011 of MIL-STD-883. Laser scribing shall be allowed only for SOS technology product and only to the backside of the wafer.
3.3.1 Terminal connections. The terminal connections shall be as specified on figure 1.
3.3.2 Block diagrams. The block diagrams shall be as specified on figure 2.
3.3.3 Schematic circuits. The schematic circuits shall be maintained by the manufacturer and made available to the qualifying activity and the preparing activity upon request.
3.3.4 Truth tables. The truth tables shall be as specified on figure 3.
3.3.5 Functional tests. The functional tests used to test this device are contained in Appendix A. If the test patterns cannot be implemented due to test equipment limitations, alternate test patterns to accomplish the same results shall be documented, maintained, and available to the acquiring activity and qualifying activity upon request.
3.3.5 Case outlines. The case outlines shall be as specified in 1.2.3.
3.4 Lead material and finish. The lead material and finish shall be in accordance with MIL-PRF-38535 (see 6.6).
3.5 Electrical performance characteristics. Unless otherwise specified, the electrical performance characteristics are as specified in table I, and apply over the full recommended case operating temperature range.
3.5.1 Post irradiation performance characteristics. The electrical performance characteristics of the RHA devices at the RHA levels are as specified in table I and apply at an ambient temperature of +25°C ± 5°C.
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the subgroups specified in table II. The electrical tests for each subgroup are described in table III.
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.
3.7.1 Serialization. All class S devices shall be serialized in accordance with MIL-PRF-38535.
3.8 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group number 41 (see MIL-PRF-38535, appendix A).