MIL-M-38510/57F
FIGURE 5. Threshold-voltage test circuit.
TABLE VII. Threshold-voltage test circuit conditions.
Device |
GND |
10 V |
VTN measured at |
GND |
-10 V |
VTP measured at |
||
-20 µA supply |
-10 µA supply |
20 µA supply |
10 µA supply |
|||||
01, 51 |
3 |
14 |
1, 4, 5, 6, 7 |
3 |
1, 4, 5, 6, 7 |
14 |
||
02, 52 |
10 |
16 |
1, 4, 5, 6, 7, 8, 9, 11, 13, 14, 15 |
10 |
1, 4, 5, 6, 7, 8, 9, 11, 13, 14, 15 |
16 |
||
03, 53 |
1 |
16 |
6, 7, 8, 9, 14, 15 |
1 |
6, 7, 8, 9, 14, 15 |
16 |
||
04, 54 |
10 |
16 |
1, 4, 5, 6, 7, 8, 9, 11, 12,13, 14, 15 |
10 |
1, 4, 5, 6, 7, 8, 9, 11, 13, 14, 15 |
16 |
||
05, 55 |
2 |
1, 10, 15, 16 |
8 |
2 |
1, 8, 10, 15 |
16 |
||
06, 56 |
10 |
9, 11, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 |
12 |
10 |
1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 13, 14, 15 |
24 |
90