TABLE III. Group A inspection for device type 05 - Continued.
symbol |
MIL- sTD- 883 method |
Cases E,F,N, z |
Terminal conditions and limits 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Recirc in |
Clock |
NC |
NC |
NC |
Q |
Q |
Vss |
Delayed clock |
Mode cont. |
NC |
NC |
NC |
NC |
Data in |
VDD |
subgroup 1 TC = 25°C |
subgroup 2 TC = 125°C |
subgroup 3 TC = -55°C |
||||||||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
Iss 2/ |
3005 |
46 47 48 49 50 51 52 53 54 55 56 57 58 59 |
GND " " " " " " " " " " " " " |
3/ " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " |
GND 15.0V GND 15.0V GND 15.0V GND 15.0V GND 15.0V GND 15.0V GND 15.0V |
15.0V " " " " " " " " " " " " " |
None " " " " " " " " " " " " " |
-2.0 " " " " " " " " " " " " " |
-20 " " " " " " " " " " " " " |
µA " " " " " " " " " " " " " |
||||||||||||||
60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 |
GND " " " " " " " " " " " " " 15.0V 15.0V GND |
3/ " " " " " " " " " " 15.0V GND 15.0V " " " |
GND " " " " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " " 15.0V 15.0V |
GND 15.0V GND 15.0V GND 15.0V GND 15.0V GND 15.0V GND 15.0V GND 15.0V GND GND 15.0V |
15.0V " " " " " " " " " " " " " " " " |
None " " " " " " " " " " Vss Vss None Vss Vss Vss |
-2.0 " " " " " " " " " " " " " " " " |
-20 " " " " " " " " " " " " " " " " |
µA " " " " " " " " " " " " " " " " |
||||||||||||||||
VOH1 |
3006 |
77 78 79 |
VIL1 4/ VIL1 4/ VIL1 4/ |
5/ 5/ VIH1 |
IOH1 6/ |
IOH2 7/ |
" " " |
IOH3 8/ |
VIL1 VIL1 VIL1 |
VIH1 9/ VIL1 VIH1 |
5.0V 5.0V 5.0V |
Q Q Delayed clock |
4.5 4.5 4.5 |
4.5 4.5 4.5 |
4.5 4.5 4.5 |
V " " |
||||||||||
VOH2 |
80 81 82 |
VIL2 10/ VIL2 10/ VIL2 10/ |
5/ 5/ VIH2 |
" " " |
VIL2 VIL2 VIL2 |
VIH2 11/ VIL2 VIH2 |
12.5V 12.5V 12.5V |
Q Q Delayed clock |
11.25 11.25 11.25 |
11.25 11.25 11.25 |
11.25 11.25 11.25 |
" " " |
||||||||||||||
VOL1 |
3007 |
83 84 85 |
VIL1 VIL1 VIL1 |
5/ 5/ VIL1 |
IOL1 12/ |
IOL2 13/ |
" " " |
IOL3 14/ |
VIL1 VIL1 VIL1 |
VIL1 VIH1 VIL1 |
5.0V 5.0V 5.0V |
Q Q Delayed clock |
0.5 0.5 0.5 |
0.5 0.5 0.5 |
0.5 0.5 0.5 |
" " " |
||||||||||
VOL2 |
86 87 88 |
VIL2 VIL2 VIL2 |
5/ 5/ VIL2 |
" " " |
VIL2 VIL2 VIL2 |
VIL2 VIH2 VIL2 |
12.5V 12.5V 12.5V |
Q Q Delayed clock |
1.25 1.25 1.25 |
1.25 1.25 1.25 |
1.25 1.25 1.25 |
" " " |
see footnotes at end of device type 05.