TABLE lll. Group A inspection for device type 02 - Continued.
Symbol |
MlL- STD- 883 method |
Cases E,F,N, z |
Terminal conditions and limits 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Pl8 |
Q6 |
Q8 |
Pl4 |
Pl3 |
Pl2 |
Pl1 |
VSS |
P/S Control |
Clock |
Serial ln |
Q7 |
Pl5 |
Pl6 |
Pl7 |
VDD |
Subgroup 7 TC = 25°C |
Subgroup 8 |
|||||||||
TC = 125°C |
TC = -55°C |
|||||||||||||||||||||||||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
Truth table test 12/ |
3014 |
107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 |
5.0V " " " " " " " " " " GND " " " " " " " " " |
L " " " " " " " " " H " " " " " " " " " " |
L " " " " " " " " " H " " " " " " " " " " |
5.0V " " " " " " " " " " GND " " " " " " " " " |
5.0V " " " " " " " " " " GND " " " " " " " " " |
5.0V " " " " " " " " " " GND " " " " " " " " " |
5.0V " " " " " " " " " " GND " " " " " " " " " |
GND " " " " " " " " " " " " " " " " " " " " |
GND " " " " " " " " 5.0V 5.0V GND " " " " " " " " " |
5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V |
GND " " " " " " " " 5.0V 5.0V GND " " " " " " " " " |
L " " " " " " " " " H " " " " " " " " " " |
5.0V " " " " " " " " " " GND " " " " " " " " " |
5.0V " " " " " " " " " " GND " " " " " " " " " |
5.0V " " " " " " " " " " GND " " " " " " " " " |
5.0V " " " " " " " " " " " " " " " " " " " " |
All outputs " " " " " " " " " " " " " " " " " " " |
See 13/ and 14/ |
See footnotes at end of device type 02.