TABLE III. Group A inspection for device type 03 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E,F,N,Z |
Terminal conditions and limits 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Clock B |
Q4B |
Q3A |
Q2A |
Q1A |
Reset A |
Data A |
VSS |
Clock A |
Q4A |
Q3B |
Q2B |
Q1B |
Reset B |
Data B |
VDD |
Subgroup 7 TC = 25°C |
Subgroup 8 |
|||||||||
TC = 125°C |
TC = -55°C |
|||||||||||||||||||||||||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
Truth table test 12/ |
3014 |
80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 |
5.0V 5.0V GND 5.0V 5.0V GND 5.0V 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND GND 5.0V |
L " " " " " " " " " " H H L L H H L L |
L " " " " " " " " H H L L H " " " L L |
L " " " " " H H H L L H " " " " " L L |
L L L H H H L L L H " " " " " " " L L |
5.0V GND " " " " " " " " " " " " " " " 5.0V 5.0V |
5.0V " " " GND GND GND 5.0V " " " " " " " " " " " |
GND " " " " " " " " " " " " " " " " " " |
5.0V 5.0V GND 5.0V 5.0V GND 5.0V 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND GND 5.0V |
L " " " " " " " " " " H H L L H H L L |
L " " " " " " " " H H L L H " " " L L |
L " " " " " H H H L L H " " " " " L L |
L L L H H H L L L H " " " " " " " L L |
5.0V GND " " " " " " " " " " " " " " " 5.0V 5.0V |
5.0V " " " GND GND GND 5.0V " " " " " " " " " " " |
5.0V " " " " " " " " " " " " " " " " " " |
All outputs " " " " " " " " " " " " " " " " " |
See 13/, 14/ |
||||||
Subgroup 9 TC = 25°C |
Subgroup 10 TC = 125°C |
Subgroup 11 TC = -55°C |
||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||||
tPHL1 |
3003 Fig. 4 |
99 100 101 102 103 |
IN |
OUT |
OUT |
OUT |
GND " " " " |
IN " " " |
GND " " " " |
IN " " " |
OUT |
OUT |
GND " " " " |
IN |
5.0V " " " " |
Clock A to Q1A Clock A to Q2A Clock A to Q3A Clock A to Q4A Clock B to Q1B |
20 " " " " |
975 " " " " |
30 " " " " |
1465 " " " " |
20 " " " " |
975 " " " " |
ns " " " " |
|||
104 105 106 |
IN " " |
OUT |
GND " " |
GND " " |
OUT |
OUT |
GND " " |
IN " " |
5.0V " " |
Clock B to Q2B Clock B to Q3B Clock B to Q4B |
20 " " |
975 " " |
30 " " |
1465 " " |
20 " " |
975 " " |
ns " " |
See footnotes at end of device type 03.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.