TABLE III. Group A inspection for device type 03 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E,F,N,Z |
Terminal conditions and limits 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Clock B |
Q4B |
Q3A |
Q2A |
Q1A |
Reset A |
Data A |
VSS |
Clock A |
Q4A |
Q3B |
Q2B |
Q1B |
Reset B |
Data B |
VDD |
Subgroup 9 TC = 25°C |
Subgroup 10 TC = 125°C |
Subgroup 11 TC = -55°C |
||||||||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
fCL (max) 15/ |
139 140 141 142 143 144 145 146 |
IN " " " |
OUT |
OUT |
OUT |
OUT |
GND " " " " " " " |
IN " " " |
GND " " " " " " " |
IN " " " |
OUT |
OUT |
OUT |
OUT |
GND " " " " " " " |
IN " " " |
5.0V " " " " " " " |
Clock A " " " Clock B " " " |
1.0 " " " " " " " |
1.4 " " " " " " " |
1.0 " " " " " " " |
µs " " " " " " " |
1/ Terminals not designated may be "HIGH" level logic, "LOW" level logic, or open except as follows: VIC(POS) tests; the VSS terminal shall be open.
VIC(NEG) tests; the VDD terminal shall be open. ISS tests; the output terminals shall be open.
2/ Test numbers 13 through 27 shall be run in sequence. See 4.5.3.
3/ Apply clock pulse; VIN = 0 V to VDD until proper output state is achieved.
4/ IOH = -80 µA at 25°C, -55 µA at 125°C, -100 µA at -55°C.
5/ VIL1 = 1.1 V at 25°C, 0.85 V at 125°C, 1.35 V at -55°C.
6/ VIH1 = 3.8 V at 25°C, 3.6 V at 125°C, 3.95 V at -55°C.
7/ VIL2 = 2.8 V at 25°C, 2.55 V at 125°C, 3.05 V at -55°C.
8/ VIH2 = 9.5 V at 25°C, 9.25 V at 125°C, 9.75 V at -55°C.
9/ IOL = 120 µA at 25°C, 85 µA at 125°C, 150 µA at -55°C.
10/ The device manufacturer may, at his option, measure IIL and IIH at 25°C for each individual input or measure all inputs together.
11/ See 4.4.1c.
12/ Test numbers 80 through 98 shall be run in sequence.
13/ The output voltage limits for each temperature are "H" = VDD -0.5 V min. and "L" = VSS +0.5 V max.
14/ The functional tests shall be performed at VIH and VDD ≤ 5.0 V and ; 15 V.
15/ The maximum clock frequency (fCL) requirement is considered met if proper output state changes occur with the pulse repetition period set to that given in the limits column.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business