TABLE III. Group A inspection for device type 55.
Symbol |
MIL- STD- 883 method |
Cases E,F,N,Z |
Terminal conditions and limits 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Recir In |
Clock |
NC |
NC |
NC |
Q |
Q |
VSS |
Delayed clock |
Mode cont |
NC |
NC |
NC |
NC |
Data In |
VDD |
Subgroup 1 TC = 25°C |
Subgroup 2 TC = 125°C |
Subgroup 3 TC = -55°C |
||||||||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
VIC (POS) |
1 2 3 4 |
1mA |
1mA |
1mA |
1mA |
GND " " " |
Recir In Clock Mode Cont Data In |
1.5 " " " |
V " " " |
|||||||||||||||||
VIC (NEG) |
5 6 7 8 |
-1mA |
-1mA |
GND " " " |
-1mA |
-1mA |
Recir In Clock Mode Cont Data In |
-6 " " " |
" " " " |
|||||||||||||||||
ISS 2/ |
3005 |
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 |
GND " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
3/ " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V GND 18.0V |
18.0V " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
None " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
-2 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
-20 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
µA " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
See footnotes at end of device type 55.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business