TABLE lll. Group A inspection for device type 54 - Continued.
Symbol |
MlL- STD- 883 method |
Cases E,F,N,Z |
Terminal conditions and limits 11 |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Pl8 |
Q6 |
Q8 |
Pl4 |
Pl3 |
Pl2 |
Pl1 |
VSS |
P1S control |
Clock |
Serial ln |
Q7 |
Pl5 |
Pl6 |
Pl7 |
VDD |
Subgroup 1 TC = 25°C |
Subgroup 2 TC = 125°C |
Subgroup 3 TC = -55°C |
||||||||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
lOH2 |
51 52 53 |
15.0V 15.0V 15.0V |
13.5V |
13.5V |
15.0V 15.0V 15.0V |
15.0V 15.0V 15.0V |
15.0V 15.0V 15.0V |
15.0V 15.0V 15.0V |
GND " " |
15.0V 15.0V 15.0V |
31 31 31 |
15.0V 15.0V 15.0V |
13.5V |
15.0V 15.0V 15.0V |
15.0V 15.0V 15.0V |
15.0V 15.0V 15.0V |
15.0V 15.0V 15.0V |
Q6 Q7 Q8 |
-3.4 -3.4 -3.4 |
-2.4 -2.4 -2.4 |
-4.2 -4.2 -4.2 |
mA mA mA |
||||
llH1 51 |
3010 |
54 |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
" |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
All inputs together |
1100 |
nA |
||||||||
llH2 |
55 56 57 58 59 60 61 62 63 64 65 |
18.0V GND " " " " " " " " " |
GND 18.0V GND " " " " " " " " |
GND GND 18.0V GND " " " " " " " |
GND GND GND 18.0V GND " " " " " " |
GND " " " 18.0V GND " " " " " |
" " " " " " " " " " " |
GND " " " " 18.0V GND " " " " |
GND " " " " " 18.0V GND " " " |
GND " " " " " " 18.0V GND " " |
GND " " " " " " " 18.0V GND " |
GND " " " " " " " " 18.0V GND |
GND " " " " " " " " " 18.0V |
" " " " " " " " " " " |
Pl8 Pl4 Pl3 Pl2 Pl1 P1S control Clock Serial ln Pl5 Pl6 Pl7 |
100 " " " " " " " " " " |
100 " " " " " " " " " " |
" " " " " " " " " " " |
||||||||
llL1 51 |
3009 |
66 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
All inputs together |
-1100 |
" |
||||||||
llL2 |
67 68 69 70 71 72 73 74 75 76 77 |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
" " " " " " " " " " " |
Pl8 Pl4 Pl3 Pl2 Pl1 P1S control Clock Serial ln Pl5 Pl6 Pl7 |
-100 " " " " " " " " " " |
-100 " " " " " " " " " " |
" " " " " " " " " " " |
||||||||
Subgroup 4 TC=25°C |
||||||||||||||||||||||||||
Min |
Max |
|||||||||||||||||||||||||
Ci |
3012 |
78 79 80 81 82 83 84 85 86 87 88 |
61 |
61 |
61 |
61 |
61 |
GND " " " " " " " " " " |
61 |
61 |
61 |
61 |
61 |
61 |
GND " " " " " " " " " " |
Pl8 Pl4 Pl3 Pl2 Pl1 P1S control Clock Serial ln Pl5 Pl6 Pl7 |
12 " " " " " " " " " " |
pF " " " " " " " " " " |
See footnotes at end of device type 54.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business