MIL-M-38510/57F
Device types 03 and 53
NOTES:
1. The pulse generators have the following characteristics: VGEN = VDD ±1 percent, tf and tr ≤ 20 ns, duty cycle = 50 percent, ZOUT = 50 n.
2. When measuring tPHL1, tPLH1, tTHL, and tTLH, set switch S1 to clock position. Momentarily set switch S2 to
position 2 to set outputs low and return to position 1.
3. When measuring tPHL2 set switch S2 to reset position. Momentarily set switch S2 to position 2 to set outputs low and return to position 1.
4. tSETUPH = tSETUPL = 350 ns at TA = 25°C and -55°C; tSETUPH = tSETUPL = 500 ns at TA = 125°C. For device types 03 and 53, tSETUPH = tSETUPL = 108 ns at TA = 25°C and -55°C; 150 ns at TA = 125°C.
5. For fCL, set switch S1 to clock. Requirements for MAX clock frequency (fCL) are established by setting
the parameter to the limits given in table III and observing proper output state changes.
FIGURE 4. Switching time test circuit and waveforms - Continued.