MIL-M-38510/57F
Device types 02 and 52
NOTES:
1. The pulse generators have the following characteristics: VGEN = VDD ±1 percent, tf and tr ≤ 20 ns, duty cycle = 50 percent, ZOUT = 50n.
2. When measuring tPHL1 and tPLH1, set parallel serial control switch S1 to "LOW". Initially, apply clock pulse
with serial/parallel inputs at 0 V to set outputs low.
3. When measuring tPHL2, tPLH2, tTHL, and tTLH, set parallel serial control switch S1 to "HI". Initially, apply clock pulses with serial/parallel inputs at 0 V to set outputs low.
4. tSETUPH = tSETUPL = 350 ns at TA = 25°C and -55°C; tSETUPH = tSETUPL = 500 ns at TA = 125°C. For device type 02, tSETUPH = tSETUPL = 130 ns at TA = 25°C and -55°C; tSETUPH = tSETUPL = 180 ns at TA = 125°C.
5. Requirements for MAX clock frequency (fCL) are established by setting the parameter to the limits given
in table III and observing proper output state changes.
FIGURE 4. Switching time test circuit and waveforms - Continued.
19