TABLE III. Group A inspection for device type 05 - Continued.
Symbol |
MIL-STD- 883 method |
Case V |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
Subgroup 8 TC = +125°C |
||||||||||
K |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
11 |
12 |
13 |
||||||||||
Test No. |
A0 |
A1 |
A2 |
A3 |
A4 |
A5 |
Q |
W |
VSS |
CE |
Min |
Max |
||||||||
ICCDR |
9/ |
72 |
9/ |
9/ |
9/ |
9/ |
9/ |
9/ |
9/ |
9/ |
GND |
9/ |
VDD |
400 |
µA |
|||||
PWR DWN |
73 |
9/ |
9/ |
9/ |
9/ |
9/ |
9/ |
9/ |
GND |
9/ |
VDD |
2.5 |
V |
|||||||
Func- tional tests |
15/ |
74 |
10/ |
10/ |
10/ |
10/ |
10/ |
10/ |
10/ |
GND |
10/ |
Q |
10/ |
10/ |
V |
|||||
Subgroup 9 TC = +25°C |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C |
||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||
tAVQV |
Fig. 4 15/ |
75 |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
GND |
11/ |
Q |
200 |
250 |
200 |
ns |
|||
tELQV |
76 |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
GND |
11/ |
Q |
220 |
280 |
220 |
ns |
||||
Subgroup 12 TC = +25°C |
||||||||||||||||||||
Min |
Max |
|||||||||||||||||||
IDDOP |
77 |
12/ |
12/ |
12/ |
12/ |
12/ |
12/ |
12/ |
12/ |
GND |
12/ |
VDD |
4.5 |
mA |
See footnotes at end of table III.