TABLE III. Group A inspection for device type 01 - Continued.
Symbol |
MIL-STD- 883 method |
Case V |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
Subgroup 1 TC = +25°C |
Subgroup 2 TC = +125°C |
Subgroup 3 TC = -55°C |
||||||||
Test No. |
A0 |
A1 |
A2 |
A3 |
A4 |
A5 |
Q |
w |
VSS |
CE |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tAVQV |
Fig. 4 |
74 |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
11/ |
GND |
11/ |
Q |
120 |
120 |
120 |
ns |
|||
tELQV |
75 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
120 |
120 |
120 |
" |
|||||
tELQX 14/ |
76 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
5 |
5 |
5 |
" |
|||||
tEHQZ 14/ |
77 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
50 |
50 |
50 |
" |
|||||
Subgroup 12 TC = +25°C |
||||||||||||||||||||
Min |
Max |
|||||||||||||||||||
IDDOP |
78 |
12/ |
12/ |
12/ |
12/ |
12/ |
12/ |
12/ |
12/ |
GND |
12/ |
7 |
mA |
See footnotes at end of table III.