MIL-M-38510/210F
TABLE IVG. Programming characteristics for circuit G.
Parameter |
Symbol |
Conditions 1/ |
Limits |
Unit |
||
Min |
Recommended |
Max |
||||
Required VCC for programming |
VCCP |
10.0 |
10.5 |
11.0 |
V |
|
ICC during programming |
ICCP |
VCC = 11 V |
750 |
mA |
||
Required output voltage for programming |
VOP |
10.0 |
10.5 |
11.0 |
V |
|
Output current while programming |
IOP |
VOUT = 11 V |
20 |
mA |
||
Rate of voltage change of VCC or output |
IRR |
1.0 |
10.0 |
V/µs |
||
Programming pulse width (enabled) |
PWE |
9 |
10 |
11 |
µs |
|
Required VCC for verification |
VCCV |
3.8 |
4.0 |
4.2 |
V |
|
Maximum duty cycle for VCC at VCCP |
MDC |
25 |
25 |
% |
||
Address set-up time |
t1 |
100 |
ns |
|||
VCCP set-up time |
t2 |
2/ |
5 |
µs |
||
VCCP hold time |
t5 |
100 |
ns |
|||
VOP set-up time |
t3 |
100 |
ns |
|||
VOP hold time |
t4 |
100 |
ns |
1/ TC = +25°C.
2/ VCCP setup time may be greater than 0 if VCCP rises at the same rate or faster than VOP.
54
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business