TABLE III. Group A inspection for device types 02 and 04 - Continued.
0utputs not designated are open or resistive coupled to GND or voltage. Terminal conditions: Inputs not designated are high � 2.0 V or s 0.8 V.
Subgroup |
Symbol |
MIL- STD- 883 method |
Case 3 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
11 |
12 |
13 |
14 |
16 |
17 |
18 |
19 |
20 |
22 |
23 |
24 |
25 |
26 |
27 |
28 |
Measured terminal |
Test limits |
Unit |
|
Cases J,K,L |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
|||||||
Test no. |
A7 |
A6 |
A5 |
A4 |
A3 |
A2 |
A1 |
A0 |
01 |
02 |
03 |
GND |
04 |
05 |
06 |
07 |
08 |
CE3 |
CE2 |
CE 1 |
A10 |
A9 |
A8 |
VCC |
Min |
Max |
|||||
1 TC=+25°C |
I0HZ |
59 60 61 62 63 64 65 66 |
5.2V |
5.2V |
5.2V |
GND " " " " " " " |
5.2V |
5.2V |
5.2V |
5.2V |
5.2V |
0.5V " " " " " " " |
0.5V " " " " " " " |
4.5V " " " " " " " |
5.5V " " " " " " " |
01 02 03 04 05 06 07 08 |
100 " " " " " " " |
µA " " " " " " " |
|||||||||||||
I0LZ |
67 68 69 70 71 72 73 74 |
0.5V |
0.5V |
0.5V |
" " " " " " " " |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
01 02 03 04 05 06 07 08 |
-100 " " " " " " " |
" " " " " " " " |
||||||||||||||
I0S |
3011 " " " " " " " |
75 76 77 78 79 80 81 82 |
14/ 2/ 15/ 16/ 17/ " " " " " |
2/ 15/ 12/ 16/ 17/ " " " " " |
2/ 15/ 16/ 17/ " " " " " " |
2/ 15/ 16/ 17/ " 20/ " " " " |
2/ 15/ 16/ 17/ " " " " " " |
17/ 2/ 15/ 16/ " " " " " " |
2/ 15/ 16/ 17/ " " " " " " |
18/ 2/ 15/ 16/ 17/ " " " " " |
GND |
GND |
GND |
" " " " " " " " |
GND |
GND |
GND |
GND |
GND |
4.5V " " " " " " " |
4.5V " " " " " " " |
0.5V " " " " " " " |
2/ 15/ 16/ 17/ " " " " " " |
2/ 15/ 16/ 17/ " " " " " " |
2/ 15/ 16/ 17/ " " " " " " |
" " " " " " " " |
01 02 03 04 05 06 07 08 |
-10 " " " " " " " |
-100 " " " " " " " |
mA " " " " " " " |
|
ICC |
3005 |
83 |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
" |
GND |
GND |
GND |
GND |
" |
VCC |
185 |
" |
||||||||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C. |
||||||||||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C. |
||||||||||||||||||||||||||||||
7 TC=+25°C |
Funct- ional tests |
4/ |
84 |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
GND |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
4/ |
0utputs |
4/ |
||
8 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC = +125°C and -55°C. |
||||||||||||||||||||||||||||||
9 TC=+25°C |
tPHL1 tPLH1 tPHL2 tPLH2 |
GALPAT Fig. 4 Sequen- tial Fig. 4 |
85 86 87 88 |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
6/ " " " |
6/ " " " |
6/ " " " |
GND " " " |
6/ " " " |
6/ " " " |
6/ " " " |
6/ " " " |
6/ " " " |
5.5V 5.5V 8/ 8/ |
5.5V 5.5V 8/ 8/ |
GND GND 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
5/ 5/ 8/ 8/ |
0utputs " " " |
7/ 7/ 9/ 9/ |
ns " " " |
|
10 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = +125°C. |
||||||||||||||||||||||||||||||
11 |
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55°C. |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business