MIL-M-38510/210F
Device types 01, 02, 03, and 04
W0RD N0. |
6/ |
6/ |
6/ |
ADDRESS |
DATA |
|||||||||||||||||
cE 1 |
cE2 |
cE3 |
A10 |
A9 |
A8 |
A7 |
A6 |
A5 |
A4 |
A3 |
A2 |
A1 |
A0 |
08 |
07 |
06 |
05 |
04 |
03 |
02 |
01 |
|
NA |
L |
H |
H |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
5/ |
5/ |
5/ |
5/ |
5/ |
5/ |
5/ |
5/ |
NA |
H |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
0c |
0c |
0c |
0c |
0c |
0c |
0c |
0c |
Device type 05
W0RD N0. |
6/ |
6/ |
ADDRESS |
DATA |
||||||||||||||
cE 1 |
cE 2 |
A11 |
A10 |
A9 |
A8 |
A7 |
A6 |
A5 |
A4 |
A3 |
A2 |
A1 |
A0 |
04 |
03 |
02 |
01 |
|
NA |
L |
L |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
5/ |
5/ |
5/ |
5/ |
NA |
H |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
x |
0c |
0c |
0c |
0c |
N0TES:
1. NA = Not applicable.
2. x = Input may be high level, low level, or open circuit.
3. 0c = 0pen circuit (high resistance output).
4. Program readout can only be accomplished with enable input at low level.
5. The outputs for an unprogrammed device shall be high for circuits A, c, (device type 05), E, F, and J and low for circuits B, c (device types 02, 04), D, G, and I.
6. Enable inputs are ANDED.
FIGURE 2. Truth table (unprogrammed).