TABLE III. Group A inspection for device types 04 and 05 - continued. 1/
Subgroup |
MIL-STD -883 method |
Test no. |
Adapter pin numbers |
Relays energized |
Pin measured |
Equation |
Limits |
||||||
No. |
Value |
Unit |
|||||||||||
13 |
14 |
Min |
Max |
Unit |
|||||||||
4 TA = +25°C (figure 2) |
AVE(REF) |
4004 |
93 |
-20.0 V |
1,2,3,5,7 |
14 |
E93 |
V |
|||||
AVE+ |
" |
94 |
" |
1,2,3,5,7 |
" |
E94 |
" |
AVE+ = 10/(E94 - E93) |
+10.0 |
V/mV |
|||
AVE- |
" |
95 |
" |
1,2,3,5,7 |
" |
E95 |
" |
AVE- = 10/(E93 - E95) |
+10.0 |
" |
|||
5 TA = +125°C (figure 2) |
AVE(REF) |
" |
96 |
" |
1,2,3,5,7 |
" |
E96 |
" |
|||||
AVE+ |
" |
97 |
" |
1,2,3,5,7 |
" |
E97 |
" |
AVE+ = 10/(E97 - E96) |
+8.0 |
" |
|||
AVE- |
" |
98 |
" |
1,2,3,5,7 |
" |
E98 |
" |
AVE- = 10/(E96 - E98) |
+8.0 |
" |
|||
6 |
(Tests 99 - 101) Same tests, terminal conditions, equations, and limits as subgroup 5 except TA = -55°C |
||||||||||||
7 TA = +25°C |
tRHLC |
102 |
300 |
ns |
|||||||||
tRLHC |
103 |
300 |
" |
||||||||||
8 TA = +125°C |
tRHLC |
104 |
500 |
" |
|||||||||
tRLHC |
105 |
640 |
" |
||||||||||
8 TA = -55°C |
tRHLC |
106 |
300 |
" |
|||||||||
tRLHC |
107 |
300 |
" |
1/ For devices marked with the "Q" certification mark, the parameters listed herein may be guaranteed if not tested to the limits specified herein in accordance with the manufacturer's QM plan.
2/ VOL1 and VOL2 use VID = -6 mV; VOL3, VOL4 use VID = -5 mV.
3/ Maximum test duration shall be 10 ms.
4/ Test numbers 39, 44, 70, and 75, which require read and record measurements plus a calculation, may be omitted except when subgroups 2 and 3 are being performed for group A sampling inspections and group C and D end points.
� Represents delta.