TABLE III. Group A inspection for device types 04 and 05 - continued. 1/
Subgroup |
Symbol |
MIL-STD -883 method |
Test no. |
Adapter PIN numbers |
|||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
||||
4 TA = +25°C (figure 2) |
AVE(REF) |
4004 |
93 |
GND |
GND |
+15.0 V |
-15.0 V |
+15.0 V |
GND |
+20.0 V |
|||||
AVE+ |
" |
94 |
" |
" |
" |
" |
" |
+10.0 V |
" |
||||||
AVE- |
" |
95 |
" |
" |
" |
" |
" |
-10.0 V |
" |
||||||
5 TA = +125°C (figure 2) |
AVE(REF) |
" |
96 |
" |
" |
" |
" |
" |
GND |
" |
|||||
AVE+ |
" |
97 |
" |
" |
" |
" |
" |
+10.0 V |
" |
||||||
AVE- |
" |
98 |
" |
" |
" |
" |
" |
-10.0 V |
" |
||||||
6 |
(Tests 99 - 101) Same tests, terminal conditions, equations, and limits as subgroup 5 except TA = -55°C. |
||||||||||||||
7 TA = +25°C |
tRHLC |
102 |
These tests shall be performed using test conditions and procedures listed on figure 5. |
||||||||||||
tRLHC |
103 |
||||||||||||||
8 TA = +125°C |
tRHLC |
104 |
These tests shall be performed using test conditions and procedures listed on figure 5. |
||||||||||||
tRLHC |
105 |
||||||||||||||
8 TA = -55°C |
tRHLC |
106 |
These tests shall be performed using test conditions and procedures listed on figure 5. |
||||||||||||
tRLHC |
107 |
See footnotes at end of device types 04 and 05.