TABLE III. Group A inspection for device type 03 - continued. 1/
Subgroup |
Symbol |
MIL-STD -883 method |
Test no. |
Relays energized |
Pin measured |
Equation |
Limits |
||||
No. |
Value |
Unit |
|||||||||
Min |
Max |
Unit |
|||||||||
2 TA = +125°C (figure 4) |
+IIB |
4001 |
24 |
1,2,3,5,6,7,9,10 |
9 |
E11 |
V |
+IIB = E8 - 10E11 |
+20 |
µA |
|
-IIB |
" |
25 |
1,3,4,5,6,7,9,10 |
" |
E12 |
" |
-IIB = 10E12 - E8 |
+20 |
µA |
||
CMRR |
4003 |
26 |
2,4,5,6,8,9,10 |
" |
E13 |
" |
CMR = 20 log [103 / (E13 - E14)] |
+80 |
dB |
||
CMRR |
4003 |
27 |
2,4,5,6,8,9,10 |
" |
E14 |
" |
|||||
+ICC |
3005 |
28 |
1,2,5 |
4 |
+ICC |
mA |
+0.5 |
+10 |
mA |
||
-ICC |
3005 |
29 |
1,2,5 |
5 |
-ICC |
mA |
-3.6 |
-0.5 |
mA |
||
VOL |
3007 |
30 |
1,2,5 |
7 |
VOL |
V |
+0.4 |
V |
|||
VOH |
3006 |
31 |
3,4,6 |
" |
VOH |
V |
+2.5 |
+5.5 |
V |
||
ICEX |
32 |
3,4,6 |
" |
ICEX |
µA |
-0.5 |
+100 |
µA |
|||
VO(STL)1 |
33 |
1,2,5 |
" |
VO(STL)1 |
V |
+2.5 |
+5.5 |
V |
|||
VO(STL)2 |
34 |
1,2,5 |
" |
VO(STL)2 |
" |
+2.5 |
+5.5 |
" |
|||
VO(STH)1 |
35 |
1,2,5 |
" |
VO(STH)1 |
" |
+0.4 |
" |
||||
VO(STH)2 |
36 |
1,2,5 |
" |
VO(STH)2 |
" |
+0.4 |
" |
||||
2 TA = +125°C (figure 2) |
ISTB1 |
37 |
1,2,5 |
6 |
ISTB1 |
mA |
-3.3 |
-0.1 |
mA |
||
ISTB2 |
38 |
1,2,5 |
10 |
ISTB2 |
mA |
-3.3 |
-0.1 |
mA |
See footnotes at end of device type 03.