TABLE 111. Group A inspection for device types 01 and 02 - continued. 1/
Subgroup |
Symbol |
M1L-STD -883 method |
Test no. |
Adapter P1N numbers |
Relays closed |
||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
|||||
2 TA = +125°C (figure 2) |
+11B |
4001 |
21 |
GND |
+12.0 V |
-6.0 V |
-1.0 V |
1,2,3,5,6,7,9,10 |
|||||
-11B |
4001 |
22 |
GND |
+12.0 V |
-6.0 V |
-1.0 V |
1,3,4,5,6,7,9,10 |
||||||
CMR |
4003 |
23 |
+5.0 V |
+17.0 V |
-2.0 V |
-6.0 V |
2,4,5,6,8,9,10 |
||||||
CMR |
4003 |
24 |
-5.0 V |
+7.0 V |
-12.0 V |
+4.0 V |
2,4,5,6,8,9,10 |
||||||
+1CC |
3005 |
25 |
GND |
2/ |
+12.0 V |
-6.0 V |
1,2,5 |
||||||
-1CC |
3005 |
26 |
" |
" |
" |
" |
1,2,5 |
||||||
VOL |
3007 |
27 |
" |
" |
" |
" |
1,2,5 |
||||||
1OL |
3009 |
28 |
" |
" |
" |
" |
1,2,5 |
||||||
VOH1 |
3006 |
29 |
" |
2/ |
" |
" |
-5 mA |
3,4,6 |
|||||
VOH2 |
3006 |
30 |
" |
" |
" |
" |
3,4,6 |
||||||
VO(STB) 3/ |
3007 |
31 |
" |
" |
" |
" |
300 mV |
3,4,6 |
|||||
1O(STB) 3/ |
3009 |
32 |
" |
" |
" |
" |
100 mV |
3,4,6 |
|||||
3 TA = -55°C (figure 2) |
V1O1 |
4001 |
33 |
" |
" |
" |
-1.8 V |
1,2,3,4,5,6,8,9,10 |
|||||
V1O2 |
" |
34 |
" |
" |
" |
-1.8 V |
2,4,5,6,8,9,10 |
||||||
�V1O/�T 4/ |
" |
35 |
Calculation: �V1O / �T = [V1O (test 33) - V1O (test 1)] x 3 / 80°C 10 |
||||||||||
11O |
" |
36 |
GND |
+12.0 V |
-6.0 V |
-1.8 V |
1,3,5,6,8,9,10 |
||||||
�11O/�T 4/ |
" |
37 |
Calculation: �11O / �T = [11O (test 36) - 11O (test 3)] x 3 / 80°C 10 |
See footnotes at end of device types 01 and 02.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business