MIL-M-38510/103H
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions 1/ 2/ -55°C ≤ TA ≤ +125°C unless otherwise specified |
Temperature |
Device type |
Limits |
Unit |
|
Min |
Max |
||||||
Input bias current |
+IIB |
VIC = 0 V, RS = 50 kn |
+25°C ≤ TA ≤ +125°C |
04,05 |
-100 |
+0.1 |
nA |
TA = -55°C |
-150 |
+0.1 |
|||||
VIC = 13 V and -14.5 V, RS = 50 kn |
+25°C ≤ TA ≤ +125°C |
-150 |
+0.1 |
||||
TA = -55°C |
-200 |
+0.1 |
|||||
VIC = 0 V |
TA = +25°C, +125°C |
06,07 |
-0.1 |
+500 |
|||
TA = -55°C |
-0.1 |
1000 |
|||||
VIC = +12 V and -12 V |
TA = +25°C, +125°C |
-0.1 |
+750 |
||||
TA = -55°C |
-0.1 |
+1000 |
|||||
-IIB |
VIC = 0 V, RS = 50 kn |
+25°C ≤ TA ≤ +125°C |
04,05 |
-100 |
+0.1 |
||
TA = -55°C |
-150 |
+0.1 |
|||||
VIC = 13 V and -14.5 V, RS = 50 kn |
+25°C ≤ TA ≤ +125°C |
-150 |
+0.1 |
||||
TA = -55°C |
-200 |
+0.1 |
|||||
VIC = 0 V |
TA = +25°C, +125°C |
06,07 |
-0.1 |
+500 |
|||
TA = -55°C |
-0.1 |
+1000 |
|||||
VIC = +12 V and -12 V |
TA = +25°C, +125°C |
-0.1 |
+750 |
||||
TA = -55°C |
-0.1 |
+1000 |
See footnotes at end of table.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.