TABLE III. Group A inspection for device types 04 and 05 - continued. 1/
Subgroup |
Symbol |
MIL-STD -883 method |
Test no. |
Adapter PIN numbers |
|||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
||||
2 TA = +125°C (figure 2) |
VIO |
4001 |
32 |
GND |
GND |
+15.0 V |
-15.0 V |
+15.0 V |
GND |
+20.0 V |
|||||
" |
33 |
" |
" |
+29.5 V |
-0.5 V |
+29.5 V |
+14.5 V |
" |
|||||||
" |
34 |
" |
" |
+2.0 V |
-28.0 V |
+2.0 V |
-13.0 V |
" |
|||||||
" |
35 |
" |
" |
+2.5 V |
-2.5 V |
+2.5 V |
GND |
" |
|||||||
VIO(R) |
" |
36 |
" |
" |
+15.0 V |
-15.0 V |
+15.0 V |
+15.0 V |
GND |
" |
|||||
" |
37 |
" |
" |
+29.5 V |
-0.5 V |
+29.5 V |
+29.5 V |
+14.5 V |
" |
||||||
" |
38 |
" |
" |
+2.0 V |
-28.0 V |
+2.0 V |
+2.0 V |
-13.0 V |
" |
||||||
�VIO/�T |
" |
39 |
Calculation = [VIO (E32) - VIO(E1)] / 100°C 4/ |
||||||||||||
IIO |
" |
40 |
GND |
GND |
+15.0 V |
-15.0 V |
+15.0 V |
GND |
+20.0 V |
||||||
" |
41 |
" |
" |
+29.5 V |
-0.5 V |
+29.5 V |
+14.5 V |
" |
|||||||
" |
42 |
" |
" |
+2.0 V |
-28.0 V |
+2.0 V |
-13.0 V |
" |
|||||||
IIO(R) |
" |
43 |
" |
" |
+15.0 V |
-15.0 V |
+15.0 V |
+15.0 V |
GND |
" |
|||||
�IIO/�T |
" |
44 |
Calculation = [IIO(test 40) - IIO(test 8)] / 100°C 4/ |
||||||||||||
+IIB |
" |
45 |
GND |
GND |
+15.0 V |
-15.0 V |
+15.0 V |
GND |
+20.0 V |
||||||
" |
46 |
" |
" |
+29.5 V |
-0.5 V |
+29.5 V |
+14.5 V |
" |
|||||||
" |
47 |
" |
" |
+2.0 V |
-28.0 V |
+2.0 V |
-13.0 V |
" |
|||||||
-IIB |
" |
48 |
" |
" |
+15.0 V |
-15.0 V |
+15.0 V |
GND |
" |
||||||
" |
49 |
" |
" |
+29.5 V |
-0.5 V |
+29.5 V |
+14.5 V |
" |
|||||||
" |
50 |
" |
" |
+2.0 V |
-28.0 V |
+2.0 V |
-13.0 V |
" |
See footnotes at end of device types 04 and 05.