TABLE III. Group A inspection for device type 03 - continued. 1/
Subgroup |
Symbol |
MIL-STD -883 method |
Test no. |
Adapter PIN numbers |
|||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
||||
4 TA = +25°C (figure 2) |
AV+ |
4004 |
59 |
GND |
+12.0 V |
-6.0 V |
-4.5 V |
||||||
AV- |
4004 |
60 |
" |
" |
" |
-0.5 V |
|||||||
5 TA = +125°C (figure 2) |
AV+ |
4004 |
61 |
" |
" |
" |
-4.5 V |
||||||
AV- |
4004 |
62 |
" |
" |
" |
-0.5 V |
|||||||
6 TA = -55°C (figure 2) |
AV+ |
4004 |
63 |
" |
" |
" |
-4.5 V |
||||||
AV- |
4004 |
64 |
" |
" |
" |
-0.5 V |
|||||||
7 TA = +25°C |
tLTHR |
65 |
These tests shall be performed using test conditions and procedures listed on figure 3. |
||||||||||
tHTHR |
66 |
||||||||||||
tSTRL1 |
67 |
These tests shall be performed using test conditions and procedures listed on figure 4. |
|||||||||||
tSTRL2 |
68 |
See footnotes at end of device type 03.