TABLE 111. Group A inspection for device types 01 and 02. 1/
Subgroup |
Symbol |
M1L-STD -883 method |
Test no. |
Adapter P1N numbers |
Relays closed |
||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
|||||
1 TA = +25°C (figure 2) |
V101 |
4001 |
1 |
GND |
+12.0 V |
-6.0 V |
-1.4 V |
1,2,3,4,5,6,8,9,10 |
|||||
V102 |
" |
2 |
" |
" |
" |
" |
2,4,5,6,8,9,10 |
||||||
110 |
" |
3 |
" |
" |
" |
" |
1,3,5,6,8,9,10 |
||||||
+11B |
" |
4 |
" |
" |
" |
" |
1,2,3,5,6,7,9,10 |
||||||
-11B |
" |
5 |
" |
" |
" |
" |
1,3,4,5,6,7,9,10 |
||||||
CMR |
4003 |
6 |
+5.0 V |
+17.0 V |
-2.0 V |
-6.4 V |
2,4,5,6,8,9,10 |
||||||
CMR |
4003 |
7 |
-5.0 V |
+7.0 V |
-12.0 V |
+3.6 V |
2,4,5,6,8,9,10 |
||||||
+1CC |
3005 |
8 |
GND |
2/ |
+12.0 V |
-6.0 V |
1,2,5 |
||||||
-1CC |
3005 |
9 |
" |
" |
" |
" |
1,2,5 |
||||||
V0L |
3007 |
10 |
" |
" |
" |
" |
1,2,5 |
||||||
10L |
3009 |
11 |
" |
" |
" |
" |
1,2,5 |
||||||
V0H1 |
3006 |
12 |
" |
2/ |
" |
" |
-5 mA |
3,4,6 |
|||||
V0H2 |
3006 |
13 |
" |
" |
" |
" |
3,4,6 |
||||||
V0(STB) 3/ |
3007 |
14 |
" |
" |
" |
" |
300 mV |
3,4,6 |
|||||
10(STB) 3/ |
3009 |
15 |
" |
" |
" |
" |
100 mV |
3,4,6 |
|||||
2 TA = +125°C (figure 2) |
V101 |
4001 |
16 |
" |
" |
" |
-1.0 V |
1,2,3,4,5,6,8,9,10 |
|||||
V102 |
4001 |
17 |
" |
" |
" |
-1.0 V |
2,4,5,6,8,9,10 |
||||||
�V10/�T 4/ |
18 |
Calculation: �V10 / �T = [V10 (test 16) - V10 (test 1)] x 3 / 100°C 10 |
|||||||||||
110 |
4001 |
19 |
GND |
+12.0 V |
-6.0 V |
-1.0 V |
1,3,5,6,8,9,10 |
||||||
�110/�T 4/ |
20 |
Calculation: �110 / �T = [110 (test 19) - 110 (test 3)] x 3 / 100°C 10 |
See footnotes at end of device types 01 and 02.