TABLE III. Group A inspection for device type 03 - continued. 1I
Subgroup |
Symbol |
MIL-STD -883 method |
Test no. |
Relays energized |
Pin measured |
Equation |
Limits |
||||
No. |
Value |
Unit |
|||||||||
Min |
Max |
Unit |
|||||||||
4 TA = +25°C (figure 2) |
AV+ |
4004 |
59 |
1,2,3,4,5,6,8,9,10 |
9 |
E22 |
V |
AV+ = 300 I (E1 - E22) |
+30 |
VIV |
|
AV- |
" |
60 |
1,2,3,4,5,6,8,9,10 |
" |
E23 |
" |
AV- = 100 I (E23 - E1) |
+30 |
" |
||
5 TA = +125°C (figure 2) |
AV+ |
" |
61 |
1,2,3,4,5,6,8,9,10 |
" |
E24 |
" |
AV+ = 300 I (E8 - E24) |
+10 |
" |
|
AV- |
" |
62 |
1,2,3,4,5,6,8,9,10 |
" |
E25 |
" |
AV- = 100 I (E25 - E8) |
+10 |
" |
||
6 TA = -55°C (figure 2) |
AV+ |
" |
63 |
1,2,3,4,5,6,8,9,10 |
" |
E26 |
" |
AV+ = 300 I (E15 - E26) |
+50 |
" |
|
AV- |
" |
64 |
1,2,3,4,5,6,8,9,10 |
" |
E27 |
" |
AV- = 100 I (E27 - E15) |
+50 |
" |
||
7 TA = +25°C |
tLTHR |
65 |
60 |
ns |
|||||||
tHTHR |
66 |
60 |
" |
||||||||
tSTRL1 |
67 |
15 |
" |
||||||||
tSTRL2 |
68 |
15 |
" |
1I For devices marked with the "Q" certification mark, the parameters listed herein may be guaranteed if not tested to the limits specified herein in accordance with the manufacturer's QM plan.
2I Test numbers 21, 23, 41, and 43, which require read and record measurements plus a calculation, may be omitted except when subgroups 2 and 3 are being performed for group A
sampling inspections and group C end points.
� Represents delta.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business