TABLE 111. Group A inspection for device type 03 - continued. 1/
Subgroup |
Symbol |
M1L-STD -883 method |
Test no. |
Relays energized |
Pin measured |
Equation |
Limits |
||||
No. |
Value |
Unit |
|||||||||
Min |
Max |
Unit |
|||||||||
3 TA = -55°C (figure 2) |
V1O1 |
4001 |
39 |
1,2,3,4,5,6,8,9,10 |
9 |
E15 |
V |
V1O = 10E15 |
-3 |
+3 |
mV |
V1O2 |
" |
40 |
2,4,5,6,8,9,10 |
9 |
E16 |
V |
V1O = 10E16 |
-3 |
+3 |
mV |
|
�V1O/�T 2/ |
" |
41 |
-10 |
+10 |
µV/°C |
||||||
11O |
" |
42 |
1,3,5,6,8,9,10 |
9 |
E17 |
V |
11O = E15 - E17 |
-7 |
+7 |
µA |
|
�11O/�T 2/ |
" |
43 |
-75 |
+75 |
nA/°C |
||||||
+11B |
" |
44 |
1,2,3,5,6,7,9,10 |
9 |
E18 |
V |
+11B = E15 - 10E18 |
+45 |
µA |
||
-11B |
" |
45 |
1,3,4,5,6,7,9,10 |
" |
E19 |
" |
-11B = 10E19 - E15 |
+45 |
µA |
||
CMRR |
4003 |
46 |
2,4,5,6,8,9,10 |
" |
E20 |
" |
CMRR = 20 log [103 / (E20 - E21)] |
+80 |
dB |
||
CMRR |
4003 |
47 |
2,4,5,6,8,9,10 |
" |
E21 |
" |
|||||
+1CC |
3005 |
48 |
1,2,5 |
4 |
+1CC |
mA |
+0.5 |
+10 |
mA |
||
-1CC |
3005 |
49 |
1,2,5 |
5 |
-1CC |
mA |
-3.6 |
-0.5 |
mA |
||
VOL |
3007 |
50 |
1,2,5 |
7 |
VOL |
V |
+1.0 |
V |
|||
VOH |
3006 |
51 |
3,4,6 |
" |
VOH |
V |
+2.5 |
+5.5 |
V |
||
1CEX |
52 |
3,4,6 |
" |
1CEX |
µA |
-0.5 |
+100 |
µA |
|||
VO(STL)1 |
53 |
1,2,5 |
" |
VO(STL)1 |
V |
+2.5 |
+5.5 |
V |
|||
VO(STL)2 |
54 |
1,2,5 |
" |
VO(STL)2 |
" |
+2.5 |
+5.5 |
" |
|||
VO(STH)1 |
55 |
1,2,5 |
" |
VO(STH)1 |
" |
+0.4 |
" |
||||
VO(STH)2 |
56 |
1,2,5 |
" |
VO(STH)2 |
" |
+0.4 |
" |
||||
1STB1 |
57 |
1,2,5 |
6 |
1STB1 |
mA |
-3.3 |
-0.1 |
mA |
|||
1STB2 |
58 |
1,2,5 |
10 |
1STB2 |
mA |
-3.3 |
-0.1 |
mA |
See footnotes at end of device type 03.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744