TABLE 111. Group A inspection for device types 04 and 05 - continued. 1/
Subgroup |
Symbol |
M1L-STD -883 method |
Test no. |
Adapter pin numbers |
Relays energized |
Pin measured |
Equation |
Limits |
|||||
No. |
Value |
Unit |
|||||||||||
13 |
14 |
Min |
Max |
Unit |
|||||||||
3 TA = -55°C (figure 2) |
VO(STB) |
4001 |
82 |
1,2,4,5,10 |
7 |
E82 |
V |
VO(STB) = E82 |
+14 |
V |
|||
CMRR |
4003 |
83 |
+80 |
dB |
|||||||||
VOL1 2/ |
3007 |
84 |
1,2,12 |
7 |
E84 |
V |
VOL1 = E84 |
+0.4 |
V |
||||
VOL2 2/ |
" |
85 |
1,2,12 |
" |
E85 |
" |
VOL2 = E85 |
+0.4 |
" |
||||
VOL3 2/ |
" |
86 |
1,2,12 |
" |
E86 |
" |
VOL3 = E86 |
+1.5 |
" |
||||
VOL4 2/ |
" |
87 |
1,2,12 |
" |
E87 |
" |
VOL4 = E87 |
+1.5 |
" |
||||
111 |
4001 |
88 |
1,2,12 |
1 |
188 |
nA |
111 = 188 |
-5 |
+500 |
nA |
|||
112 |
4001 |
89 |
1,2,12 |
2 |
189 |
nA |
112 = 189 |
-5 |
+500 |
nA |
|||
+1CC |
3005 |
90 |
1,2 |
4 |
190 |
mA |
+1CC = 190 |
+7.0 |
mA |
||||
-1CC |
3005 |
91 |
1,2 |
5 |
191 |
" |
-1CC = 191 |
-6.0 |
" |
||||
1OS 3/ |
3011 |
92 |
1,2 |
7 |
192 |
" |
1OS = 192 |
+250 |
" |
See footnotes at end of device types 04 and 05.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business