TABLE 111. Group A inspection for device types 01 and 02 - continued. 1/
Subgroup |
Symbol |
M1L-STD -883 method |
Test no. |
Adapter P1N numbers |
Relays closed |
||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
|||||
3 TA = -55°C (figure 2) |
+11B |
4001 |
38 |
GND |
+12.0 V |
-6.0 V |
-1.8 V |
1,2,3,5,6,7,9,10 |
|||||
-11B |
4001 |
39 |
GND |
+12.0 V |
-6.0 V |
-1.8 V |
1,3,4,6,7,9,10 |
||||||
CMR |
4003 |
40 |
+5.0 V |
+17.0 V |
-2.0 V |
-6.8 V |
2,4,5,6,8,9,10 |
||||||
CMR |
4003 |
41 |
-5.0 V |
+7.0 V |
-12.0 V |
+3.2 V |
2,4,5,6,8,9,10 |
||||||
+1CC |
3005 |
42 |
GND |
2/ |
+12.0 V |
-6.0 V |
1,2,5 |
||||||
-1CC |
3005 |
43 |
" |
" |
" |
" |
1,2,5 |
||||||
VOL |
3007 |
44 |
" |
" |
" |
" |
1,2,5 |
||||||
1OL |
3009 |
45 |
" |
" |
" |
" |
1,2,5 |
||||||
VOH1 |
3006 |
46 |
" |
2/ |
" |
" |
-5 mA |
3,4,6 |
|||||
VOH2 |
3006 |
47 |
" |
" |
" |
" |
3,4,6 |
||||||
VO(STB) 3/ |
3007 |
48 |
" |
" |
" |
" |
300 mV |
3,4,6 |
|||||
1O(STB) 3/ |
3009 |
49 |
" |
" |
" |
" |
100 mV |
3,4,6 |
|||||
4 TA = +25°C (see figure 2) |
AV+ |
4004 |
50 |
" |
" |
" |
-1.9 V |
1,2,3,4,5,6,8,9,10 |
|||||
AV- |
" |
51 |
" |
" |
" |
-0.9 V |
1,2,3,4,5,6,8,9,10 |
||||||
5 TA = +125°C (see figure 2) |
AV+ |
" |
52 |
" |
" |
" |
-1.5 V |
1,2,3,4,5,6,8,9,10 |
|||||
AV- |
" |
53 |
" |
" |
" |
-0.5 V |
1,2,3,4,5,6,8,9,10 |
See footnotes at end of device types 01 and 02.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business