TABLE III. Group A inspection for device type 05 - Continued.
Terminal conditions (outputs not designated are open or resistive coupled to GND or voltage; inputs not designated are high � 2.0 V, low s 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases J,K |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
Measured terminal |
Test limits |
Unit |
|
Test no. |
A7 |
A6 |
A5 |
A4 |
A3 |
A2 |
A1 |
A0 |
01 |
02 |
03 |
GND |
04 |
05 |
06 |
07 |
08 |
N1C |
N1C |
CE |
N1C |
A9 |
A8 |
VCC |
Min |
Max |
|||||
1 TC = +25°C |
I0HZ |
50 51 52 53 54 55 56 57 |
5.2V |
5.2V |
5.2V |
GND " " " " " " " |
5.2V |
5.2V |
5.2V |
5.2V |
5.2V |
5.5V " " " " " " " |
5.5V " " " " " " " |
01 02 03 04 05 06 07 08 |
100 " " " " " " " |
µA " " " " " " " |
|||||||||||||||
I0LZ |
58 59 60 61 62 63 64 65 |
0.5V |
0.5V |
0.5V |
" " " " " " " " |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
" " " " " " " " |
" " " " " " " " |
01 02 03 04 05 06 07 08 |
-100 " " " " " " " |
µA " " " " " " " |
||||||||||||||||
I0S |
3011 |
66 67 68 69 70 71 72 73 |
11 " " " " " " " |
11 " " " " " " " |
11 " " " " " " " |
11 " " " " " " " |
11 91 " " " " " " " |
11 91 " " " " " " " |
11 91 " " " " " " " |
11 91 201 " " " " " " " |
GND |
GND |
GND |
" " " " " " " " |
GND |
GND |
GND |
GND |
GND |
0.5V " " " " " " " |
11 91 131 201 " " " " " " |
11 " " " " " " " |
" " " " " " " " |
01 02 03 04 05 06 07 08 |
-15 " " " " " " " |
" " " " " " " " |
µA " " " " " " " |
||||
ICC |
3005 |
74 |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
" |
GND |
GND |
GND |
" |
VCC |
185 |
mA |
|||||||||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C and VIC tests are omitted. |
||||||||||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||||||||||||
7 TC = +25°C |
Func- tional tests |
41 |
75 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
GND |
41 |
41 |
41 |
41 |
41 |
GND |
41 |
41 |
41 |
0utputs |
41 |
|||||
8 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC = +125°C and TC = -55°C. |
||||||||||||||||||||||||||||||
9 TC = +25°C |
tPHL1 tPLH1 tPHL2 tPLH2 |
GALPAT Fig. 6 GALPAT Fig. 6 Sequen- tial Fig. 6 Sequen- tial Fig. 6 |
76 77 78 79 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
61 " " " |
61 " " " |
61 " " " |
GND " " " |
61 " " " |
61 " " " |
61 " " " |
61 " " " |
61 " " " |
GND GND 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
0utputs " " " |
81 " " " |
ns " " " |
||||
10 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = +125°C. |
||||||||||||||||||||||||||||||
11 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = -55°C. |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business