TABLE III. Group A inspection for device type 01.
Terminal conditions (outputs not designated are open or resistive coupled to GND or voltage; inputs not designated are high � 2.0 V, low s 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases V,X |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
Meas. terminal |
Test limits |
Unit |
|
Test no. |
A6 |
A5 |
A4 |
A3 |
A0 |
A1 |
A2 |
A10 |
GND |
CE 1 |
04 |
03 |
02 |
01 |
A9 |
A8 |
A7 |
VCC |
Min |
Max |
|||||
1 TC = +25°C |
VIC |
1 2 3 4 5 6 7 8 9 10 11 12 |
-10mA |
-10mA |
-10mA |
-10mA |
-10mA |
-10mA |
-10mA |
-10mA |
GND " " " " " " " " " " " |
-10mA |
-10mA |
-10mA |
-10mA |
4.5V " " " " " " " " " " " |
A6 A5 A4 A3 A0 A1 A2 A10 CE 1 A9 A8 A7 |
-1.5 " " " " " " " " " " " |
V " " " " " " " " " " " |
||||||
V0L |
3007 |
13 14 15 16 |
11 21 " " " |
11 " " " |
11 " " " |
11 " " " |
11 " " " |
11 " " " |
11 " " " |
11 " " " |
" " " " |
0.5V " " " |
31 |
31 |
31 |
31 |
11 " " " |
11 " " " |
11 " " " |
" " " " |
04 03 02 01 |
0.5 " " " |
V " " " |
||
IIL |
3009 |
17 18 19 20 21 22 23 24 25 26 27 28 |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
" " " " " " " " " " " " |
0.5V |
0.5V |
0.5V |
0.5V |
5.5V " " " " " " " " " " " |
A6 A5 A4 A3 A0 A1 A2 A10 CE 1 A9 A8 A7 |
-1.0 " " " " " " " " " " " |
-250 " " " " " " " " " " " |
µA " " " " " " " " " " " |
|||||
IIH |
3010 |
29 30 31 32 33 34 35 36 37 38 39 40 |
5.5V |
5.5V |
5.5V |
5.5V |
5.5V |
5.5V |
5.5V |
5.5V |
" " " " " " " " " " " " |
5.5V |
5.5V |
5.5V |
5.5V |
" " " " " " " " " " " " |
A6 A5 A4 A3 A0 A1 A2 A10 A9 A8 A7 CE 1 |
50 " " " " " " " " " " " |
µA " " " " " " " " " " " |
||||||
ICEX |
41 42 43 44 |
" " " " |
" " " " |
5.2V |
5.2V |
5.2V |
5.2V |
" " " " |
04 03 02 01 |
100 " " " |
µA " " " |
||||||||||||||
ICC |
3005 |
45 |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
" |
GND |
GND |
GND |
GND |
" |
VCC |
170 |
mA |
||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C and VIC tests are omitted. |
||||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||||||
7 TC = +25°C |
Func- tional tests |
41 |
46 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
GND |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
0utputs |
41 |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business