TABLE III. Group A inspection for device type 03 - Continued.
Terminal conditions (outputs not designated are open or resistive coupled to GND or voltage; inputs not designated are high � 2.0 V, low s 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases J,K |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
Measured terminal |
Test limits |
Unit |
|
Test no. |
A7 |
A6 |
A5 |
A4 |
A3 |
A2 |
A1 |
A0 |
01 |
02 |
03 |
GND |
04 |
05 |
06 |
07 |
08 |
CE4 |
CE3 |
CE 2 |
CE 1 |
A9 |
A8 |
VCC |
Min |
Max |
|||||
1 TC = +25°C |
ICEX |
55 56 57 58 |
GND " " " |
5.2V |
5.2V |
5.2V |
5.2V |
0.5V " " " |
0.5V " " " |
5.5V " " " |
5.5V " " " |
5.5V " " " |
05 06 07 08 |
100 " " " |
µA " " " |
||||||||||||||||
ICC |
3005 |
59 |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
" |
GND |
GND |
GND |
GND |
GND |
GND |
" |
VCC |
185 |
mA |
|||||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C and VIC tests are omitted. |
||||||||||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||||||||||||
7 TC = +25°C |
Func- tional tests |
41 |
60 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
GND |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
0utputs |
41 |
||
8 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC = +125°C and TC = -55°C. |
||||||||||||||||||||||||||||||
9 TC = +25°C |
tPHL1 tPLH1 tPHL2 tPLH2 |
GALPAT Fig. 6 GALPAT Fig. 6 Sequen- tial Fig. 6 Sequen- tial Fig. 6 |
61 62 63 64 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
61 " " " |
61 " " " |
61 " " " |
GND " " " |
61 " " " |
61 " " " |
61 " " " |
61 " " " |
61 " " " |
5.5V 5.5V 71 71 |
5.5V 5.5V 71 71 |
GND GND 71 71 |
GND GND 71 71 |
51 51 71 71 |
51 51 71 71 |
51 51 71 71 |
0utputs " " " |
81 " " " |
ns " " " |
|
10 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = +125°C. |
||||||||||||||||||||||||||||||
11 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = -55°C. |
See footnotes at end of table.