MIL-M-38510/5558
TA8LE III
Table III which forms a part of this specification is not printed herein because of its extreme length, and even when presented as a hard copy, it requires conversion to on-line format. When the sequence or conditions of tests and test vectors are needed as part of inspection, it may be obtained in a form compatible with test system architecture. The preparing activity, Defense Supply Center Columbus, (DSCC) may be consulted for information on obtaining
table III. Group A subgroup assignment is shown on table I.
Functional tests are performed under the following conditions for group A subgroups 7 and 8.
Symbol |
Parameter |
Unit |
VDD |
4.5 and 5.5 |
Volts |
VSS |
0 |
Volts |
VIH |
VOH minimum ** |
Volts |
VIL |
VOL maximum ** |
Volts |
VOH |
�(VOH minimum + VOL maximum)/2 |
Volts |
VOL |
<(VOH minimum + VOL maximum)/2 |
Volts |
f |
12 |
MHz |
** Values of VOH and VOL may be obtained from table I.
Switching tests are performed with VIH = VDD and VIL = 0 V as input test conditions.