TABLE lll. Group A inspection for device type 54 - Continued.
Symbol |
MlL- STD- 883 method |
Cases E,F,Z |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Symbol |
J |
Kd |
H |
G |
F |
E |
Kb |
VSS |
Kc |
Ka |
D |
C |
B |
A |
EX |
VDD |
Subgroup 1 TC = +25°C |
Subgroup 2 TC = +125°C |
Subgroup 3 TC = -55°C |
|||||||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
lOH1 |
107 108 109 110 111 112 113 114 115 |
4.6V " " " " " " " " |
5.0V " " " " " " " " |
GND GND 5.0V " " " " " " |
GND 5.0V GND 5.0V " " " " " |
GND 5.0V 5.0V GND 5.0V " " " " |
GND 5.0V " " GND 5.0V " " " |
GND " " " " " " " " |
GND " " " " " " " " |
GND 5.0V " " " " " " " |
GND 5.0V " " " " " " " |
GND 5.0V " " " GND 5.0V " " |
GND 5.0V " " " " GND 5.0V 5.0V |
GND 5.0V " " " " " GND 5.0V |
GND 5.0V " " " " " " GND |
GND " " " " " " " " |
5.0V " " " " " " " " |
J " " " " " " " " |
-0.51 " " " " " " " " |
-0.36 " " " " " " " " |
-0.64 " " " " " " " " |
mA " " " " " " " " |
||||
lOH2 |
116 117 118 119 120 121 122 123 124 |
13.5V " " " " " " " " |
15.0V " " " " " " " " |
GND GND 15.0V " " " " " " |
GND 15.0V GND 15.0V " " " " " |
GND 15.0V 15.0V GND 15.0V " " " " |
GND 15.0V " " GND 15.0V " " " |
" " " " " " " " " |
" " " " " " " " " |
GND 15.0V " " " " " " " |
GND 15.0V " " " " " " " |
GND 15.0V " " " GND 15.0V " " |
GND 15.0V " " " " GND 15.0V 15.0V |
GND 15.0V " " " " " GND 15.0V |
GND 15.0V " " " " " " GND |
" " " " " " " " " |
15.0V " " " " " " " " |
" " " " " " " " " |
-3.4 " " " " " " " " |
-2.4 " " " " " " " " |
-4.2 " " " " " " " " |
" " " " " " " " " |
||||
llH1 3/ |
3010 |
125 |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
" |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
All inputs together |
13 |
nA |
||||||
llH2 |
126 127 128 129 130 131 132 133 134 135 136 137 138 |
18.0V GND " " " " " " " " " " " |
GND 18.0V GND " " " " " " " " " " |
GND GND 18.0V GND " " " " " " " " " |
GND " " 18.0V GND " " " " " " " " |
GND " " " 18.0V GND " " " " " " " |
GND " " " " 18.0V GND " " " " " " |
" " " " " " " " " " " " " |
GND " " " " " 18.0V GND " " " " " |
GND " " " " " " 18.0V GND " " " " |
GND " " " " " " " 18.0V GND " " " |
GND " " " " " " " " 18.0V GND " " |
GND " " " " " " " " " 18.0V GND " |
GND " " " " " " " " " " 18.0V GND |
GND " " " " " " " " " " " 18.0V |
" " " " " " " " " " " " " |
Kd H G F E Kb Kc Ka D C B A EX |
1 " " " " " " " " " " " " |
45 " " " " " " " " " " " " |
" " " " " " " " " " " " " |
||||||
llL1 3/ |
3009 |
139 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
All inputs together |
-13 |
" |
||||||
llL2 |
140 141 142 143 144 145 146 147 148 149 150 151 152 |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
" " " " " " " " " " " " " |
Kd H G F E Kb Kc Ka D C B A EX |
-1.0 " " " " " " " " " " " " |
-45 " " " " " " " " " " " " |
" " " " " " " " " " " " " |
||||||
lOC1 |
153 |
18.0V |
" |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
" |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
" |
" |
J |
25 |
90 |
25 |
" |
||||
lOC2 |
154 |
GND |
" |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
" |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
18.0V |
" |
" |
J |
-25 |
-90 |
-25 |
" |
See footnotes at end of device type 54.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business