TABLE III. Group A inspection for device type 01 - Continued.
Symbol |
MIL- STD- 883 method |
Cases A,C,D,T,X,Y |
Terminal conditions 1/ |
|||||||||
Symbol |
2aY |
2aS |
2A |
2bS |
2bY |
1A |
VSS |
1bY |
3bS |
3A |
||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
||
CI |
3012 |
41 42 43 |
(5) 2/ " " |
GND " " |
12/ |
GND " " |
12/ |
GND " " |
GND " " |
12/ |
||
tPHL |
3003 (Fig. 4) |
44 45 46 |
(5) " " |
5.0V " " |
GND IN GND |
GND " " |
(1) " " |
IN GND GND |
GND " " |
(13) " " |
GND " " |
GND GND IN |
tPLH |
47 48 49 |
" " " |
" " " |
GND IN GND |
" " " |
" " " |
IN GND GND |
" " " |
" " " |
" " " |
GND GND IN |
|
tTHL |
3004 (Fig. 4) |
50 51 52 |
" " " |
" " " |
GND IN GND |
" " " |
" " " |
IN GND GND |
" " " |
" " " |
" " " |
GND GND IN |
tTLH |
53 54 55 |
" " " |
" " " |
GND IN GND |
" " " |
‘ " " |
IN GND GND |
" " " |
" " " |
" " " |
GND GND IN |
1/ Pins not designated may be "high" level logic, "low" level logic, or open. Exceptions are as follows: For VIC(POS) tests, the VSS terminal shall be open; for VIC(NEG) tests, the VDD terminal shall be open; for ISS tests, the outputs shall be open.
2/ Terminals in parentheses are connected together as indicated by the included number.
3/ IOH1 = -0.1 mA at +25°C; -0.1 mA at +125°C; -0.1 mA at -55°C.
4/ IOH2 = -0.30 mA at +25°C; -0.21 mA at +125°C; -0.375 mA at -55°C.
5/ VIL1 = 0.9 V at +25°C; 0.65 V at +125°C; 0.95 V at -55°C.
6/ VIL2 = 2.25 V at +25°C; 1.95 V at +125°C; 2.40 V at -55°C.
7/ IOL1 = 0.23 mA at +25°C; 0.23 mA at +125°C; 0.23 mA at -55°C.
8/ VIH1 = 3.95 V at +25°C; 3.85 V at +125°C; 4.05 V at -55°C.
9/ IOL2 = 600 µA at +25°C; 400 µA at +125°C; 750 µA at -55°C.
10/ VIH2 = 10.25 V at +25°C; 10.0 V at +125°C; 10.5 V at -55°C.
11/ The device manufacturer may, at his option, measure IIL and IIH at +25°C for each individual input or measure all inputs together.
12/ See 4.4.1c.