MIL-M-38510/53F
NOTES:
1. Pulse generator has the following characteristics: VGEN = VDD ±1%, tPL = 1.0 ±0.1 µs, tr and tf ≤ 10 ns .
2. RL = 1.0 kn ±5 % and CL = 50 pF ±5 % including wiring and probe capacitance.
3. See table III for complete terminal conditions.
4. RL = 1.0 kn ±5 % to VDD for tPLZ.
FIGURE 16. Switching time test circuit and waveforms for device types 04 and 54 (Kd to output).
26