MIL-M-38510/53F
NOTES:
1. Pulse generator has the following characteristics: VGEN = VDD ±1%, tPL = 1.0 ±0.1 µs, tr and tf ≤ 10 ns .
2. RL = 200 kn ±10 % and CL = 50 pF ±5 % including wiring and probe capacitance.
3. See table III for complete terminal conditions.
FIGURE 12. Switching time test circuit and waveforms for device types 04 and 54 (AND/OR gate).
22
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business