TABLE III. Group A inspection for device type 51.
Symbol |
MIL- STD- 883 method |
Cases A, C,D,T,X,Y |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
Symbol |
2aY |
2aS |
2A |
2bS |
2bY |
1A |
VSS |
1bY |
3bS |
3A |
3aS |
3Y |
1aY |
VDD |
Subgroup 1 TC = +25°C |
Subgroup 2 TC = +125°C |
Subgroup 3 TC = -55°C |
|||||||
Test no. |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
VIC(POS) |
1 2 3 |
(5) 2/ " " |
GND " " |
1mA |
(1) 2/ " " |
1mA |
(13) 2/ " " |
1mA |
GND " " |
(8) 2/ " " |
GND " " |
1A 2A 3A |
1.5 " " |
V " " |
||||||||||
VIC(NEG) |
4 5 6 |
" " " |
-1mA |
GND " " |
" " " |
-1mA |
GND " " |
" " " |
GND " " |
" " " |
1A 2A 3A |
-6 " " |
" " " |
|||||||||||
ISS 3/ |
3005 |
7 8 |
" " |
18.0V 18.0V |
GND 18.0V |
" " |
" " |
GND 18.0V |
" " |
" " |
" " |
GND 18.0V |
18.0V 18.0V |
" " |
18.0V 18.0V |
VSS VSS |
-50 -50 |
-500 -500 |
nA nA |
|||||
VOH5 |
3006 |
9 10 11 |
" " " |
15.0V " " |
GND " " |
" " " |
" " " |
GND " " |
" " " |
" " " |
" " " |
GND " " |
15.0V " " |
" " " |
15.0V " " |
1aY 2aY 3Y |
14.95 " " |
14.95 " " |
14.95 " " |
V " " |
||||
VOL6 |
3007 |
12 13 14 |
" " " |
" " " |
" 15.0V GND |
" " " |
" " " |
15.0V GND GND |
" " " |
" " " |
" " " |
" " 15.0V |
" " " |
" " " |
" " " |
1aY 2aY 3Y |
0.05 " " |
0.05 " " |
0.05 " " |
" " " |
||||
VIH1 4/ |
15 16 17 |
" " " |
5.0V " " |
GND 4.0V GND |
" " " |
" " " |
4.0V GND GND |
" " " |
" " " |
" " " |
GND GND 4.0V |
5.0V " " |
" " " |
5.0V " " |
1aY 2aY 3Y |
0.5 " " |
0.5 " " |
0.5 " " |
" " " |
|||||
VIH2 4/ |
18 19 20 |
" " " |
10.0V " " |
GND 8.0V GND |
" " " |
" " " |
8.0V GND GND |
" " " |
" " " |
" " " |
GND GND 8.0V |
10.0V " " |
" " " |
10.0V " " |
1aY 2aY 3Y |
1.0 " " |
1.0 " " |
1.0 " " |
" " " |
|||||
VIH3 4/ |
21 22 23 |
" " " |
15.0V " " |
GND 12.0V GND |
" " " |
" " " |
12.0V GND GND |
" " " |
" " " |
" " " |
GND GND 12.0V |
15.0V " " |
" " " |
15.0V " " |
1aY 2aY 3Y |
1.5 " " |
1.5 " " |
1.5 " " |
" " " |
|||||
VIL1 4/ |
24 25 26 |
" " " |
5.0V " " |
GND 1.0V GND |
" " " |
" " " |
1.0V GND GND |
" " " |
" " " |
" " " |
GND GND 1.0V |
5.0V " " |
" " " |
5.0V " " |
1aY 2aY 3Y |
4.5 " " |
4.5 " " |
4.5 " " |
" " " |
|||||
VIL2 4/ |
27 28 29 |
" " " |
10.0V " " |
GND 2.0V GND |
" " " |
" " " |
2.0V GND GND |
" " " |
" " " |
" " " |
GND GND 2.0V |
10.0V " " |
" " " |
10.0V " " |
1aY 2aY 3Y |
9.0 " " |
9.0 " " |
9.0 " " |
" " " |
|||||
VIL3 4/ |
30 31 32 |
" " " |
15.0V " " |
GND 3.0V GND |
" " " |
" " " |
3.0V GND GND |
" " " |
" " " |
" " " |
GND GND 3.0V |
15.0V " " |
" " " |
15.0V " " |
1aY 2aY 3Y |
13.5 " " |
13.5 " " |
13.5 " " |
" " " |
|||||
IOL1 |
33 34 35 |
" " 0.4V " |
5.0V " " |
GND 5.0V GND |
" " " |
" " " |
5.0V GND GND |
" " " |
" " " |
" " " |
GND GND 5.0V |
5.0V " " |
0.4V |
" 0.4V " " |
5.0V " " |
1aY 2aY 3Y |
0.51 " " |
0.36 " " |
0.64 " " |
mA " " |
||||
IOL2 |
36 37 38 |
" " 1.5V " |
15.0V " " |
GND 15.0V GND |
" " " |
" " " |
15.0V GND GND |
" " " |
" " " |
" " " |
GND GND 15.0V |
15.0V " " |
1.5V |
" 1.5V " " |
15.0V " " |
1aY 2aY 3Y |
3.4 " " |
2.4 " " |
4.2 " " |
" " " |
||||
IOH1 |
39 40 41 |
" " 4.6V " |
" " " |
5.0V GND 5.0V |
" " " |
" " " |
GND 5.0V 5.0V |
" " " |
" " " |
" " " |
5.0V 5.0V GND |
" " " |
4.6V |
" 4.6V " " |
5.0V " " |
1aY 2aY 3Y |
-0.51 " " |
-0.36 " " |
-0.64 " " |
mA " " |
||||
IOH2 |
42 43 44 |
" " 13.5V " |
15.0V " " |
15.0V GND 15.0V |
" " " |
" " " |
GND 15.0V 15.0V |
" " " |
" " " |
" " " |
15.0V 15.0V GND |
15.0V " " |
13.5V |
" 13.5V " " |
15.0V " " |
1aY 2aY 3Y |
-3.4 " " |
-2.4 " " |
-4.2 " " |
" " " |
See footnotes at end of device type 51.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business