TABLE III. Group A inspection for device type 01 - Continued.
Symbol |
MIL- STD- 883 method |
Cases A,C,D,T,X,Y |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||
Symbol |
3aS |
3Y |
1aY |
VDD |
Subgroup 1 TA = 25°C |
Subgroup 2 TA = 125°C |
Subgroup 3 TA = -55°C |
|||||||
Test no. |
11 |
12 |
13 |
14 |
Min |
Max |
Min |
Max |
Min |
Max |
||||
VIC(POS) |
1 2 3 |
GND " " |
(8) 2/ " " |
GND " " |
1A 2A 3A |
1.5 " " |
V " " |
|||||||
VIC(NEG) |
4 5 6 |
" " " |
1A 2A 3A |
-6 " " |
" " " |
|||||||||
ISS |
3005 |
7 8 |
15.0V 15.0V |
" " |
15.0V 15.0V |
VSS VSS |
-50 -50 |
-500 -500 |
nA nA |
|||||
VOH1 |
3006 |
9 10 11 |
4.5V " " |
IOH1 |
" IOH1 " " |
4.5V " " |
1aY 2aY 3Y |
2.5 " " |
2.5 " " |
2.5 " " |
V " " |
|||
VOH2 |
12 13 14 |
5.0V " " |
IOH2 |
" IOH2 " " |
5.0V " " |
1aY 2aY 3Y |
4.5 " " |
4.5 " " |
4.5 " " |
" " " |
||||
VOH3 |
15 16 17 |
" " " |
" " " |
" " " |
1aY 2aY 3Y |
4.95 " " |
4.95 " " |
4.95 " " |
" " " |
|||||
VOH4 |
18 19 20 |
12.5V " " |
" " " |
12.5V " " |
1aY 2aY 3Y |
11.25 " " |
11.25 " " |
11.25 " " |
" " " |
|||||
VOL1 |
3007 |
21 22 23 |
5.5V " " |
IOL1 |
" IOL1 " " |
5.5V " " |
1aY 2aY 3Y |
0.4 " " |
0.5 " " |
0.4 " " |
" " " |
|||
VOL2 |
24 25 26 |
5.0V " " |
IOL2 |
" IOL2 " " |
5.0V " " |
1aY 2aY 3Y |
0.5 " " |
" " " |
0.5 " " |
" " " |
||||
VOL3 |
27 28 29 |
" " " |
" " " |
" " " |
1aY 2aY 3Y |
50 " " |
50 " " |
50 " " |
mV dc " " |
|||||
VOL4 |
30 31 32 |
12.5V " " |
" " " |
12.5V " " |
1aY 2aY 3Y |
1.25 " " |
1.25 " " |
1.25 " " |
V " " |
|||||
IIH1 11/ |
3010 |
33 |
15.0V |
" |
15.0V |
All inputs together |
300.0 |
nA |
||||||
IIH2 |
34 35 36 |
" " " |
" " " |
" " " |
1A 2A 3A |
100.0 " " |
100.0 " " |
" " " |
||||||
IIL1 11/ |
3009 |
37 |
" |
" |
" |
All inputs together |
-300.0 |
" |
||||||
IIL2 |
38 39 40 |
" " " |
" " " |
" " " |
1A 2A 3A |
-100.0 " " |
-100.0 " " |
" " " |