TABLE III. Group A inspection for device type 05 - Continued.
Terminal conditions: 0utputs not designated are open or resistive coupled to GND or voltage; input not designated are high � 2.0 V, low s 0.8 V, or open.
Subgroup |
Symbol |
MIL-STD- 883 method |
Case Y |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
Measured terminal |
Test limits |
Unit |
|
Test no. |
A0 |
A1 |
A2 |
A3 |
A4 |
01 |
02 |
03 |
04 |
GND |
05 |
06 |
07 |
08 |
CE 1 |
A5 |
A6 |
A7 |
A8 |
VCC |
Min |
Max |
|||||
1 TC=25°C |
I0HZ |
47 48 49 50 51 52 53 54 |
5.2V |
5.2V |
5.2V |
5.2V |
GND " " " " " " " |
5.2V |
5.2V |
5.2V |
5.2V |
5.5V " " " " " " " |
5.5V " " " " " " " |
01 02 03 04 05 06 07 08 |
100 " " " " " " " |
µA " " " " " " " |
|||||||||||
I0LZ |
55 56 57 58 59 60 61 62 |
0.5V |
0.5V |
0.5V |
0.5V |
" " " " " " " " |
0.5V |
0.5V |
0.5V |
0.5V |
" " " " " " " " |
" " " " " " " " |
01 02 03 04 05 06 07 08 |
-100 " " " " " " " |
µA " " " " " " " |
||||||||||||
ICC |
3005 |
63 |
GND |
GND |
GND |
GND |
GND |
" |
GND |
GND |
GND |
GND |
GND |
" |
VCC |
-10 |
-100 |
mA |
|||||||||
I0S |
3011 " " " " " " " |
64 65 66 67 68 69 70 71 |
11 " " " " " " 221 |
11 " " " " " " 221 |
11 " " " " " " 221 |
11 " " " " " " 221 |
11 " " " " " " 221 |
GND |
GND |
GND |
GND |
" " " " " " " " |
GND |
GND |
GND |
GND |
0.5V " " " " " " " |
11 " " " " " " 221 |
11 " " " " " " 221 |
11 " " " " " " 221 |
11 " " " " " " 221 |
" " " " " " " " |
01 02 03 04 05 06 07 08 |
" " " " " " " " |
" " " " " " " " |
mA " " " " " " " |
|
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = 125°C and VIC tests are omitted. |
||||||||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||||||||
7 TC=25°C |
Func- tional test |
3014 |
72 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
GND |
61 |
61 |
61 |
61 |
GND |
61 |
61 |
61 |
61 |
61 |
0utputs |
61 |
||
8 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC = 125°C and TC = -55°C. |
||||||||||||||||||||||||||
9 TC=25°C |
tPLH1 tPHL1 tPLH2 tPHL2 |
GALPAT Fig. 6 GALPAT Fig. 6 Sequential Fig. 6 Sequential Fig. 6 |
73 74 75 76 |
71 71 81 81 |
71 71 81 81 |
71 71 81 81 |
71 71 81 81 |
71 71 81 81 |
91 " " " |
91 " " " |
91 " " " |
91 " " " |
GND " " " |
91 " " " |
91 " " " |
91 " " " |
91 " " " |
GND GND 81 81 |
71 71 81 81 |
71 71 81 81 |
71 71 81 81 |
71 71 81 81 |
71 71 81 81 |
0utputs " " " |
80 80 40 40 |
ns " " " |
|
10 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = 125°C. |
||||||||||||||||||||||||||
11 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = -55°C. |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business