TABLE III. Group A inspection for device type 52 - Continued.
Symbol |
MIL- STD- 883 test method |
Cases E,F,N, Z |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
|||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Subgroup 7 TA = 25°C |
Subgroup 8 |
||||||||||
Test no. |
Q2 |
Q2 |
CLK2 |
RS2 |
K2 |
J2 |
SET2 |
VSS |
SET1 |
J1 |
K1 |
RS1 |
CLK1 |
Q1 |
Q1 |
VDD |
TA = 125°C |
TA = -55°C |
|||||||||
Truth table test |
3014 " " " " " " " " " " " " |
170 171 172 173 174 175 176 177 178 179 180 181 182 |
H " " L " " H L " " H " " |
L " " H " " L H " " " " " |
5.0V 5.0V GND 5.0V 5.0V GND 5.0V 5.0V GND 5.0V 5.0V GND 5.0V |
GND " " " " " " 5.0V " " " " " |
GND 5.0V " " " " " " " " GND " " |
GND " " " 5.0V " " " " " GND " " |
5.0V GND " " " " " " " " 5.0V " " |
GND " " " " " " " " " " " " |
5.0V GND " " " " " " " " 5.0V " " |
GND " " " 5.0V " " " " " GND " " |
GND 5.0V " " " " " " " " GND " " |
GND " " " " " " 5.0V " " " " " |
5.0V 5.0V GND 5.0V 5.0V GND 5.0V 5.0V GND 5.0V 5.0V GND 5.0V |
L " " H " " L H " " " " " |
H " " L " " H L " " H " " |
5.0V " " " " " " " " " " " " |
All outputs " " " " " " " " " " " |
See 8/ and 9/ |
|||||||
Subgroup 9 TA = 25°C |
Subgroup 10 TA = 125°C |
Subgroup 11 TA = -55°C |
|||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
||||||||||||||||||||||
tPHL |
3003 Fig. 12 " |
183 184 185 186 |
OUT |
OUT |
IN IN |
GND " " " |
IN IN |
OUT |
OUT |
5.0V " " " |
CLK2 to Q2 CLK2 to Q2 CLK1 to Q1 CLK1 to Q1 |
13 " " " |
575 " " " |
18 " " " |
865 " " " |
13 " " " |
575 " " " |
ns " " " |
|||||||||
tPHL R or S |
3003 Fig. 13 " |
187 188 189 190 |
OUT |
OUT |
IN |
IN |
" " " " |
IN |
IN |
OUT |
OUT |
" " " " |
RS2 to Q 2 SET2 to Q2 RS1 to Q 1 SET1 to Q1 |
13 " " " |
600 " " " |
18 " " " |
900 " " " |
13 " " " |
600 " " " |
" " " " |
|||||||
tPLH |
3003 Fig. 12 " |
191 192 193 194 |
OUT |
OUT |
IN IN |
" " " " |
IN IN |
OUT |
OUT |
" " " " |
CLK2 to Q2 CLK2 to Q2 CLK1 to Q1 CLK1 to Q1 |
13 " " " |
625 " " " |
18 " " " |
940 " " " |
13 " " " |
625 " " " |
" " " " |
|||||||||
tPLH R or S |
3003 Fig. 13 " |
195 196 197 198 |
OUT |
OUT |
IN |
IN |
" " " " |
IN |
IN |
OUT |
OUT |
" " " " |
SET2 to Q2 RS2 to Q2 SET1 to Q1 RS1 to Q1 |
13 " " " |
400 " " " |
18 " " " |
600 " " " |
13 " " " |
400 " " " |
" " " " |
|||||||
tTHL |
3004 Fig. 12 " |
199 200 201 202 |
OUT |
OUT |
IN IN |
" " " " |
IN IN |
OUT |
OUT |
" " " " |
Q2 Q2 Q1 Q1 |
10 " " " |
325 " " " |
14 " " " |
490 " " " |
10 " " " |
325 " " " |
" " " " |
|||||||||
tTLH |
" " " " |
203 204 205 206 |
OUT |
OUT |
IN IN |
" " " " |
IN IN |
OUT |
OUT |
" " " " |
Q2 Q2 Q1 Q1 |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
|||||||||
fCL(max) 10/ |
" " |
207 208 |
OUT |
IN |
" " |
IN |
OUT |
" " |
CLK2 CLK1 |
1.0 1.0 |
1.4 1.4 |
1.0 1.0 |
µs " |
See footnotes at end of device type 52.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business