MIL-M-38510/51F
NOTES:
1. To implement test numbers 59 thru 62 (device type 02) and 43 thru 46(device type 52), place SW3 in position 1. Set the flip-flop by momentarily placing SW1 in position 2. Following the return of SW1 to position 1, momentarily place SW2 in position 2. Measure the output levels at Q and Q to insure compliance with table III limits.
2. To implement test numbers 63 thru 66 (device type 02) and 47 thru 50 (device type 52), set the flip-flop as described in note 1. Place SW3 in position 2. Momentarily place SW2 in position 2. Following the return of SW2 to position 1, measure the output levels at Q and Q to insure compliance with table III limits.
3. Identical measurements are obtained from either flip-flop number 1 or flip-flop number 2.
4. SW1 and SW2 are momentary contact switches.
FIGURE 10. J and K input voltage high and low test circuit for device types 02 and 52.