TABLE III. Group A inspection for device type 53 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E,F, N, z |
Terminal conditions 1/ |
Measured terminal |
Limits |
Unit |
||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Subgroup 9 TC = 25°C |
Subgroup 10 TC = 125°C |
Subgroup 11 TC = -55°C |
||||||||
Test no. |
Q12 |
Q13 |
Q14 |
Q6 |
Q5 |
Q7 |
Q4 |
VSS |
Q1 |
CLOCK |
RESET |
Q9 |
Q8 |
Q10 |
Q11 |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tPHL1 6/ |
3003 " " " " " " " " " " " |
70 71 72 73 74 75 76 77 78 79 80 81 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
GND " " " " " " " " " " " |
OUT |
IN " " " " " " " " " " " |
GND " " " " " " " " " " " |
OUT |
OUT |
OUT |
OUT |
5.0V " " " " " " " " " " " |
CLOCK TO OUTPUT " " " " " " " " " " |
.013 .052 .065 .078 .091 .104 .117 .130 .143 .156 .169 .182 |
0.55 1.54 1.87 2.20 2.53 2.86 3.19 3.52 3.85 4.18 4.51 4.84 |
.018 .072 .090 .108 .126 .144 .162 .180 .198 .216 .234 .252 |
0.77 2.15 2.62 3.08 3.54 4.00 4.47 4.93 5.39 5.85 6.31 6.78 |
.013 .052 .065 .078 .091 .104 .117 .130 .143 .156 .169 .182 |
0.55 1.54 1.87 2.20 2.53 2.86 3.19 3.52 3.85 4.18 4.51 4.84 |
µs " " " " " " " " " " " |
tPLH1 |
" " " " " " " " " " " " |
82 83 84 85 86 87 88 89 90 91 92 93 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " " " " " |
OUT |
" " " " " " " " " " " " |
" " " " " " " " " " " " |
OUT |
OUT |
OUT |
OUT |
" " " " " " " " " " " " |
" " " " " " " " " " " " |
.013 .052 .065 .078 .091 .104 .117 .130 .143 .156 .169 .182 |
0.55 1.54 1.87 2.20 2.53 2.86 3.19 3.52 3.85 4.18 4.51 4.84 |
.018 .072 .090 .108 .126 .144 .162 .180 .198 .216 .234 .252 |
0.77 2.15 2.62 3.08 3.54 4.00 4.47 4.93 5.39 5.85 6.31 6.78 |
.013 .052 .065 .078 .091 .104 .117 .130 .143 .156 .169 .182 |
0.55 1.54 1.87 2.20 2.53 2.86 3.19 3.52 3.85 4.18 4.51 4.84 |
" " " " " " " " " " " " |
tPHL2 |
94 |
OUT |
OUT |
" |
OUT |
OUT |
OUT |
OUT |
" |
OUT |
" |
IN |
OUT |
OUT |
OUT |
OUT |
" |
RESET TO OUTPUT |
13 |
450 |
18 |
630 |
13 |
450 |
ns |
|
tTHL |
3004 |
95 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
" |
" |
" |
" |
OUTPUT |
10 |
200 |
14 |
280 |
10 |
280 |
ns |
tTLH |
3004 |
96 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
" |
" |
" |
" |
OUTPUT |
10 |
200 |
14 |
280 |
10 |
280 |
ns |
See footnotes at end of device type 55.