TABLE III. Group A inspection for device type 53.
Symbol |
MIL- STD- 883 method |
Cases E,F, N, z |
Terminal conditions 11 |
Measured terminal |
Limits |
Unit |
||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Subgroup 1 TC = 25°C |
Subgroup 2 TC = 125°C |
Subgroup 3 TC = -55°C |
||||||||
Test no. |
Q12 |
Q13 |
Q14 |
Q6 |
Q5 |
Q7 |
Q4 |
VSS |
Q1 |
CLOCK |
RESET |
Q9 |
Q8 |
Q10 |
Q11 |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
VIC (POS) |
1 |
1mA |
1mA |
GND |
EACH INPUT |
1.5 |
V |
|||||||||||||||||||
VIC 21 (NEG) |
2 |
GND |
-1mA |
-1mA |
EACH INPUT |
-6 |
V |
|||||||||||||||||||
IIL1 61 |
3009 |
3 |
" |
GND |
GND |
18.0V |
ALL INPUTS TOGETHER |
-200.0 |
nA |
|||||||||||||||||
IIL2 |
3009 |
4 |
" |
GND |
GND |
" |
EACH INPUT |
-100.0 |
-100.0 |
" |
||||||||||||||||
IIH1 |
3010 |
5 |
" |
18.0V |
18.0V |
" |
ALL INPUTS TOGETHER |
200.0 |
" |
|||||||||||||||||
IIH2 |
3010 |
6 |
" |
18.0V |
18.0V |
" |
EACH INPUT |
100.0 |
100.0 |
" |
||||||||||||||||
IOL |
7 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
" |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
41 |
EACH OUTPUT |
41 |
41 |
41 |
41 |
41 |
41 |
mA |
|
IOH |
8 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
mA |
|
VOL |
3007 |
9 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
V |
VOH |
3006 |
10 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
VIL |
11 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
EACH INPUT |
" |
" |
" |
" |
" |
" |
" |
|
VIH |
12 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
EACH INPUT |
" |
" |
" |
" |
" |
" |
" |
|
ISS 51 |
3005 " " " " " |
13 14 15 16 17 18 |
" " " " " " |
GND GND PU GND PU 18.0V |
18.0V GND " " " " |
18.0V " " " " " |
VSS VSS None VSS None VSS |
-1.0 " " " " " |
-10.0 " " " " " |
µA " " " " " |
||||||||||||||||
Subgroup 4 TC = 25°C |
||||||||||||||||||||||||||
Min |
Max |
|||||||||||||||||||||||||
Ci 31 |
19 |
GND |
IN |
IN |
GND |
EACH INPUT |
12 |
pF |
See footnotes at end of device type 55.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business