TABLE III. Group A inspection for device type 02 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E,F, N, z |
Terminal conditions 4/ |
Measured terminal |
Limits |
Unit |
||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Subgroup 9 TC = 25°C |
Subgroup 10 TC = 125°C |
Subgroup 11 TC = -55°C |
||||||||
Test no. |
DATA |
JAM 1 |
JAM 2 |
Q2 |
Q1 |
Q3 |
JAM 3 |
VSS |
JAM 4 |
PRESET ENABLE |
Q4 |
JAM 5 |
Q5 |
CLOCK |
RESET |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tPHL1 1/ 2/ tPHL1 |
3003 " |
74 75 |
IN " |
GND " |
GND " |
OUT |
OUT |
OUT |
GND " |
GND " |
GND " |
GND " |
OUT |
GND " |
OUT |
IN " |
GND " |
5.0V " |
CLOCK TO OUTPUT |
.013 " |
1.45 1.80 |
.018 " |
2.18 2.70 |
.013 " |
1.45 1.80 |
µs " |
tPLH1 tPLH1 |
" " |
76 77 |
" " |
" " |
" " |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
OUT |
" " |
OUT |
" " |
" " |
" " |
CLOCK TO OUTPUT |
" " |
1.45 1.80 |
" " |
2.18 2.70 |
" " |
1.45 1.80 |
" " |
tPLH2 tPLH2 |
" " |
78 79 |
" " |
" " |
" " |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
OUT |
" " |
OUT |
" " |
IN IN |
" " |
RESET TO OUTPUT |
" " |
1.45 1.80 |
" " |
2.18 2.70 |
" " |
1.45 1.80 |
" " |
tTHL tTHL |
3004 " |
80 81 |
" " |
" " |
" " |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
OUT |
" " |
OUT |
" " |
GND GND |
" " |
OUTPUTS OUTPUTS |
10 .010 |
550 2.25 |
14 .014 |
825 3.38 |
10 .010 |
550 2.25 |
ns µs |
tTLH1 1/ 2/ tTLH1 |
3004 " |
82 83 |
IN " |
GND " |
GND " |
OUT |
OUT |
OUT |
GND " |
GND " |
GND " |
GND GND |
OUT |
" " |
OUT |
" " |
GND GND |
" " |
OUTPUTS OUTPUTS |
10 .010 |
550 2.25 |
14 .014 |
825 3.38 |
10 .010 |
550 2.25 |
ns µs |
tSHL1 2/ |
84 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
IN |
" |
" |
" |
" |
" |
" |
PRESET TO CLOCK |
750 |
1125 |
750 |
ns |
||||
tSHL2 |
85 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
" |
" |
" |
IN |
" |
RESET TO CLOCK |
750 |
1125 |
750 |
" |
||||
tSHL3 |
86 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
" |
" |
" |
GND |
" |
DATA TO CLOCK |
500 |
750 |
500 |
" |
||||
tSLH3 |
87 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
" |
" |
" |
GND |
" |
DATA TO CLOCK |
500 |
750 |
500 |
" |
See footnotes at end of device type 05.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business