TABLE III. Group A inspection for device type 52 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E,F, N, z |
Terminal conditions 1/ |
Measured terminal |
Limits |
Unit |
||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Subgroup 9 TC = 25°C |
Subgroup 10 TC = 125°C |
Subgroup 11 TC = -55°C |
||||||||
Test no. |
DATA |
JAM 1 |
JAM 2 |
Q2 |
Q1 |
Q3 |
JAM 3 |
VSS |
JAM 4 |
PRESET ENABLE |
Q4 |
JAM 5 |
Q5 |
CLOCK |
RESET |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tPHL1 6/ tPHL1 |
3003 " |
66 67 |
IN " |
GND " |
GND " |
OUT |
OUT |
OUT |
GND " |
GND " |
GND " |
GND " |
OUT |
GND " |
OUT |
IN " |
GND " |
5.0V " |
CLOCK TO OUTPUT |
13 13 |
700 700 |
18 18 |
980 980 |
13 13 |
700 700 |
ns " |
tPLH1 tPLH1 |
" " |
68 69 |
" " |
" " |
" " |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
OUT |
" " |
OUT |
" " |
" " |
" " |
CLOCK TO OUTPUT |
13 13 |
700 700 |
18 18 |
980 980 |
13 13 |
700 700 |
" " |
tPLH2 tPLH2 |
" " |
70 71 |
" " |
" " |
" " |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
OUT |
" " |
OUT |
" " |
IN IN |
" " |
RESET TO OUTPUT |
13 13 |
700 700 |
18 18 |
980 980 |
13 13 |
700 700 |
" " |
tTHL tTHL |
3004 " |
72 73 |
" " |
" " |
" " |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
OUT |
" " |
OUT |
" " |
GND " |
" " |
OUTPUT |
10 10 |
250 250 |
14 14 |
350 350 |
10 10 |
250 250 |
" " |
tTLH tTLH |
" " |
74 75 |
" " |
" " |
" " |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
OUT |
" " |
OUT |
IN " |
GND " |
" " |
OUTPUT OUTPUT |
10 10 |
250 250 |
14 14 |
350 350 |
10 10 |
250 250 |
" " |
tSHL1 6/ |
76 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
IN |
" |
" |
" |
" |
" |
" |
PRESET TO CLOCK |
400 |
560 |
400 |
" |
||||
tSHL2 |
77 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
" |
" |
" |
IN |
" |
RESET TO CLOCK |
400 |
560 |
400 |
" |
||||
tSHL3 |
78 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
" |
" |
" |
GND |
" |
DATA TO CLOCK |
200 |
280 |
200 |
" |
||||
tSLH3 |
79 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
GND |
" |
" |
" |
" |
GND |
" |
DATA TO CLOCK |
200 |
280 |
200 |
" |
See footnotes at end of device type 55.