TABLE III. Group A inspection for device type 51 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E,F,N, z |
Terminal conditions 1/ |
Measured terminal |
Limits |
Unit |
||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Subgroup 4 TC = 25°C |
||||||||||
Test no. |
5 OUT |
1 OUT |
0 OUT |
2 OUT |
6 OUT |
7 OUT |
3 OUT |
VSS |
8 OUT |
4 OUT |
9 OUT |
CARRY OUT |
CLOCK ENABLE |
CLOCK |
RESET |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
CI 3/ |
3012 |
33 |
GND |
IN |
IN |
IN |
GND |
EACH INPUT |
12.0 |
pF |
||||||||||||||||
Subgroup 7 TC = 25°C |
Subgroup 8 |
|||||||||||||||||||||||||
TC = 125°C |
TC = -55°C |
|||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||||
Truth table test 5/ |
3014 " " " " " " " " " " " " " " " " " " " " " " " " " |
34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 |
L L L L L L H L L L L L L L L L x H H L L L x H L L |
L L H L L L L L L L L L H H H L x L L L L H x L L L |
H H L L L L L L L L L H L L L L x L L H H L x L H H |
L L L H L L L L L L L L L L L H x L L L L L x L L L |
L L L L L L L H L L L L L L L L x L L L L L x L L L |
L L L L L L L L H L L L L L L L x L L L L L x L L L |
L L L L H L L L L L L L L L L L x L L L L L x L L L |
GND " " " " " " " " " " " " " " " " " " " " " " " " " |
L L L L L L L L L H L L L L L L x L L L L L x L L L |
L L L L L H L L L L L L L L L L x L L L L L x L L L |
L L L L L L L L L L H L L L L L x L L L L L x L L L |
H H H H H H L L L L L H H H H H x L L H H H x L H H |
GND " " " " " " " " " " " " 5.0 V 5.0 V GND " " " " " " " " " " |
5.0 V 5.0 V PA " " " " " " " " " " 5.0 V PA 5.0 V PC 5.0 V GND GND GND 5.0 V PD 5.0 V 5.0 V 5.0 V |
5.0 V GND " " " " " " " " " " " " " " " " " 5.0 V GND " " " 5.0 V GND |
5.0 V 5.0 V " " " " " " " " " " " " " " " " " " " " " " " " |
EACH OUTPUT " " " " " " " " " " " " " " " " " " " " " " " " |
|||||||
Subgroup 9 TC = 25°C |
Subgroup 10 TC = 125°C |
Subgroup 11 TC = -55°C |
||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||||
tPHL1 6/ tPHL1 |
3003 " |
60 61 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
GND " |
OUT |
OUT |
OUT |
OUT |
GND " |
IN " |
GND " |
5.0 V " |
CLOCK TO OUTPUT |
.013 " |
0.80 1.0 |
.018 " |
1.12 1.40 |
.013 " |
0.80 1.0 |
µs " |
tPLH1 tPLH1 |
" " |
62 63 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" " |
OUT |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
CLOCK TO OUTPUT |
" " |
0.80 1.0 |
" " |
1.12 1.40 |
" " |
0.80 1.0 |
" " |
tPLH2 tPLH2 |
" " |
64 65 |
OUT |
" " |
OUT |
" " |
" " |
IN " |
" " |
RESET TO OUTPUT |
" " |
1.0 0.80 |
" " |
1.40 1.12 |
" " |
1.0 0.80 |
" " |
|||||||||
tPHL2 |
" |
66 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" |
OUT |
OUT |
OUT |
" |
" |
" |
" |
RESET TO OUTPUT |
" |
1.0 |
" |
1.40 |
" |
1.0 |
" |
||
tTHL tTHL |
3004 " |
67 68 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" " |
OUT |
OUT |
OUT |
OUT |
" " |
" " |
GND " |
" " |
OUTPUT OUTPUT |
10 10 |
200 200 |
14 14 |
280 280 |
10 10 |
200 200 |
ns " |
tTLH tTLH |
3004 " |
69 70 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" " |
OUT |
OUT |
OUT |
OUT |
" " |
" " |
" " |
" " |
OUTPUT OUTPUT |
10 10 |
360 360 |
14 14 |
504 504 |
10 10 |
360 360 |
" " |
tSHL1 tSHL1 |
See Fig. 8 6/ |
71 72 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
" " |
OUT |
OUT |
OUT |
OUT |
IN IN |
" " |
" " |
" " |
CLOCK ENABLE TO CLOCK CLOCK ENABLE TO CLOCK |
240 240 |
336 336 |
240 240 |
" " |
|||
tSHL2 |
73 |
OUT |
" |
GND |
" |
IN |
" |
RESET TO CLOCK |
400 |
560 |
400 |
" |
See footnotes at end of device type 55.