TABLE III. Group A inspection for device types 03and 04 - Continued.
Subgroup |
Symbol |
Test no. |
Adapter pin numbers 1/ |
Energized relays |
Measured pin |
Equation 2/ |
Device Types |
Limits |
Unit |
||||||
4 |
6 |
7 thru 18 |
22 thru 37 |
No. |
value |
Unit |
Min |
Max |
|||||||
6 TA = -55°C |
IFS |
223 |
+15 v |
-15 v |
1111 1111 1111 |
1111 1111 1111 1111 |
K1 |
19 |
I83 |
mA |
IFS = I83 |
03, 04 |
-2.7 |
-1.6 |
mA |
+PSS |
224 225 226 |
+13.5 v +15 v +16.5 v |
" " " |
1111 1111 1111 " " |
0000 0000 0000 1111 " " |
None " " |
21 " " |
E179 E180 E181 |
v " " |
+PSS = 0.41 (E180 - E179) +PSS = 0.41 (E180 - E179) |
03 " " |
-0.08 " " |
0.08 " " |
LSB/%PS " " |
|
-PSS |
227 228 229 |
+15 v " " |
-13.5 v -15 v -16.5 v |
" " " |
" " " |
" " " |
" " " |
E182 E183 E184 |
" " " |
-PSS = 0.41 (E183 - E182) -PSS = 0.41 (E183 - E184) |
03, 04 " " |
-0.2 " " |
0.2 " " |
" " " |
|
7 TA = 25°C |
LE |
230 231 |
+15 v " " " " " " " |
-15 v " " " " " " " |
0000 0000 0001 0000 0000 0010 0000 0000 0011 1111 1111 1100 1111 1111 1101 1111 1111 1110 |
1111 1111 1110 1111 1111 1111 1101 1111 1111 1111 1100 1111 0000 0000 0011 1111 0000 0000 0010 1111 0000 0000 0001 1111 |
" " " " " " " " |
" " " " " " " " |
E185 E186 E187 E….. E….. E4278 E4279 E4280 |
" " " " " " " " |
For each input code N calculate the Corresponding linearity error in LSB. LE = 4.1((E119-E120)(N/4095) + E120 -EA) Where EA = measured value E185 through E4280 N = DUT input digital code word in decimal form. Thus for 12 bits N = (A1)(2 exp 11) + (A2) (2 exp 10)+ … +(A12)(2 exp 0) A1, A2, … A12 are 0 or 1. E119 and E120 correspond to the error amplifier Outputs at full scale and zero scale Respectively. Worst positive error Worst positive code Worst negative error Worst negative code |
" " " " " " " " " " " " " " " " " " " |
0 - -0.5 - |
0.5 --- 0 --- |
LSB OCT LSB OCT |
This subgroup checks all digital input codes, Except zero code (vOS) and fullscale code (vFS) which were determined in Test No. 123. |
|||||||||||||||
8 TA = 125°C |
LE |
232 233 |
Same tests, terminal conditions and limits as in subgroup 7, tests 232 thru 233 except TA = 125°C. vOS and vFS are the values determined in subgroup 2. |
" " " " |
0 - -0.5 - |
0.5 - 0 - |
LSB OCT LSB OCT |
||||||||
dIZS /dt |
234 |
Calculate dIZS/dt = (IZS at 125°C − IZS at 25°C)/100°C from tests 37 and 122 respectively. |
" |
-0.01 |
0.01 |
LSB/°C |
|||||||||
dAE /dt |
235 |
Calculate dAE/dt = (AE at 125°C − AE at 25°C)/100°C from tests 38 and 123 respectively. |
03 04 |
-30 -10 |
30 10 |
PPM/°C PPM/°C |
|||||||||
dBPOE /dt |
236 |
Calculate dBPOE /dt = (BPOE at 125°C − BPOE at 25°C)/100°C from tests 39 and 124 respectively. |
03 04 |
-0.12 -0.04 |
0.12 0.04 |
LSB/°C " |
|||||||||
dBZE /dt |
237 |
Calculate dBZE /dt = (BZE at 125°C − BZE at 25°C)/100°C from tests 41 and 126 respectively. |
03, 04 |
-0.04 |
0.04 |
" |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business