TABLE III. Group A inspection for device types 03 and 04 - Continued.
Subgroup |
Symbol |
Test no. |
Adapter pin numbers 1/ |
Energized relays |
Measured pin |
Equation 2/ |
Device Types |
Limits |
Unit |
||||||
4 |
6 |
7 thru 18 |
22 thru 37 |
No. |
value |
Unit |
Min |
Max |
|||||||
2 TA = 125°C |
LE16 LE19 |
57 58 59 60 |
+15 v " " " |
-15 v " " " |
0000 0000 0001 0000 0000 0010 0000 0000 0100 0000 0000 1000 |
1111 1111 1111 1111 1111 1111 1101 1111 1111 1111 1011 1111 1111 1111 0111 1111 |
None " " " |
21 " " " |
E30 E31 E32 E33 |
v " " " |
S = ((E10 - E11)/4095) |
03, 04 " " " |
-0.5 " " " |
0.5 " " " |
LSB " " " |
LE20 LE23 |
61 62 63 64 |
" " " " |
" " " " |
0000 0001 0000 0000 0010 0000 0000 0100 0000 0000 1000 0000 |
1111 1110 1111 1111 1111 1101 1111 1111 1111 1011 1111 1111 1111 0111 1111 1111 |
" " " " |
" " " " |
E34 E35 E36 E37 |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
||
LE24 LE25 |
65 66 |
" " " " " " " " |
" " " " " " " " |
A. Record, (0000 BBBB BBBB), the sum of the codewords from tests 57 - 64 with positive linearity errors. B. Record, (0000 CCCC CCCC), the sum of the codewords from tests 57 - 64 with negative linearity errors. |
" " |
" " |
" " |
" " |
|||||||
Determine the sum of the recorded code-words obtained from tests 42 - 56 from tests 57 - 64 for positive errors. Measure and calculate linearity error for the new DUT code-word (XXXX BBBB BBBB). (See Table I, Note 9/) |
" " " |
" " " |
" " " |
" " " |
|||||||||||
XXXX BBBB BBBB XXXX BBBB BBBB 1111 |
None |
" |
E38 |
" |
LE24 = 4.1(E11 + ((on-bits) x S) - E38) |
||||||||||
Determine the sum of the recorded code-words obtained from tests 42 - 56 from tests 57 - 64 for negative errors. Measure and calculate linearity error for the new DUT code-word (yyyy CCCC CCCC). (See Table I, Note 9/) |
" " " |
" " |
" " |
" " |
|||||||||||
yyyy CCCC CCCC yyyy CCCC CCCC 1111 |
None |
" |
E39 |
" |
LE25 = 4.1(E11 + ((on-bits) x S) - E39) |
||||||||||
MCE |
67 68 69 70 71 72 73 74 75 76 77 78 |
" " " " " " " " " " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " " " " " " " " " |
0111 1111 1111 1000 0000 0000 0011 1111 1111 0100 0000 0000 0001 1111 1111 0010 0000 0000 0000 1111 1111 0001 0000 0000 0000 0111 1111 0000 1000 0000 0000 0011 1111 0000 0100 0000 0000 0001 1111 0000 0010 0000 0000 0000 1111 0000 0001 0000 0000 0000 0111 0000 0000 1000 0000 0000 0011 0000 0000 0100 0000 0000 0001 0000 0000 0010 0000 0000 0000 0000 0000 0001 |
1000 0000 0000 1111 0111 1111 1111 1111 1100 0000 0000 1111 1011 1111 1111 1111 1110 0000 0000 1111 1101 1111 1111 1111 1111 0000 0000 1111 1110 1111 1111 1111 1111 1000 0000 1111 1111 0111 1111 1111 1111 1100 0000 1111 1111 1011 1111 1111 1111 1110 0000 1111 1111 1101 1111 1111 1111 1111 0000 1111 1111 1110 1111 1111 1111 1111 1000 1111 1111 1111 0111 1111 1111 1111 1100 1111 1111 1111 1011 1111 1111 1111 1110 1111 1111 1111 1101 1111 1111 1111 1111 1111 1111 1111 1110 1111 |
" " " " " " " " " " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " " " " " " " " " |
E40 E41 E42 E43 E44 E45 E46 E47 E48 E49 E50 E51 E52 E53 E54 E55 E56 E57 E58 E59 E60 E61 E62 E63 |
" " " " " " " " " " " " " " " " " " " " " " " " |
For each set of major carry codes N and N + 1 Calculate the associated error in LSB's as Follows: MCE = 4.1 (EA - EB) where EB = measured value from E40,E42,E44,etc. EA = measured value from E41,E43,E45,etc. |
" " " " " " " " " " " " " " " " " " " " " " " " |
-1.0 " " " " " " " " " " " " " " " " " " " " " " " |
1.0 " " " " " " " " " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " " " " " " " " " |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744