TABLE III. Group A inspection for device types 01 and 02 - continued.
Subgroup |
Symbol |
Test no. |
Test condition |
Measured pin |
Equation |
Device Types |
Limits |
Unit |
|||
No. |
Value |
Unit |
Min |
Max |
|||||||
8 TA = 125°c |
tSLH |
265 |
Vcc = +5 V VEE = -15 V VIN switched from all inputs at logic "0" to all inputs at Logic "1" figure 3 |
9 |
t1 |
∝s |
tSLH = t1 |
01, 02 |
---- |
3.0 |
∝s |
tSHL |
266 |
Vcc = +5 V VEE = -15 V VIN switched from all inputs at logic "1" to all inputs at Logic "0" figure 3 |
9 |
t2 |
∝s |
tSHL = t2 |
01, 02 |
---- |
3.0 |
∝s |
|
Ri |
267 |
Vcc = +5 V VEE = -15 V Vref = 10 V figure 4 |
5 |
I88 |
mA |
Ri = 10/I88 |
01 |
15 |
25 |
kν |
|
N02 |
268 |
Vcc = +5 V VEE = -15 V VIN = all inputs at logic "1" |
9 |
V12526 |
mV |
N02 = V12526/100 |
01 02 |
---- ---- |
60 100 |
∝Vrms |
1/ Apply +15 Vdc to adapter pin1.
Apply -15 Vdc to adapter pin 2.
connect power supply ground to adapter pins 3 and 5.
1/(01/4096) 410
2/ The power supplies for device types 02 are varied by 5% (i.e. 15 x 0.05 = 0.75).
3/ The calculation of G1 can be found in test no. 132 in this table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business